Search
`
November 1, 2024

Analysis: No Knock Out Blow for Clean Power Plan Foes in Court Arguments

By Rich Heidorn Jr.

WASHINGTON — Obama administration lawyers squared off with opponents of the Clean Power Plan last week, as oral arguments scheduled for less than four hours stretched over seven.

We won’t know for months how those whose opinions count — 10 judges of the D.C. Circuit Court of Appeals — scored the arguments. And whatever they decide will inevitably be reviewed by the Supreme Court.

But based on the judges’ questions and comments, four of the five challenges — a Constitutional issue; a bill drafting error; EPA’s alleged failure to provide sufficient notice of changes between the original and final plan; and a claim that it relied on dubious assumptions on the growth of renewables — appeared to have little chance of prevailing.

‘Beyond the Fence Line’

For opponents, the best hope of overturning the CPP is likely the argument that was presented first, led by West Virginia Solicitor General Elbert Lin.

Lin contended that EPA overreached its authority by creating CO2 emission limits that coal-fired generators can’t meet, forcing a “generation switch” to natural gas and renewables.

“Ninety-six percent of [West Virginia’s] power comes from coal,” he said. The rule, he said, was “clearly designed to make us change our generation source.”

Judge Brett M. Kavanaugh evidenced the most sympathy for the “beyond-the-fence-line” argument.

The CPP seeks to cut the power sector’s carbon emissions by 32% by 2030, compared with 2005 levels. It uses two different CO2 emission rates to define the “best system of emission reduction,” one for coal-steam and oil-steam plants and a second for natural gas plants. The agency said compliance can be achieved through improving generators’ efficiency (Building Block one) and shifting generation from coal to lower-emitting natural gas plants (Building Block two) and zero‐emitting renewables (Building Block three).

Citing what he said was at least three decades of Supreme Court precedent, Kavanaugh said EPA needed explicit Congressional approval for the magnitude of the changes contemplated by the CPP. “This is a huge case,” he said. EPA is “fundamentally transforming the industry.”

Justice Department attorney Eric Hostetler, speaking for EPA, insisted the agency is entitled to deference under the Supreme Court’s Chevron decision, which held that courts should defer to agencies’ interpretations of the laws they are charged with enforcing unless the court finds their actions unreasonable.

“This is far from the first time EPA has relied on generation-shifting,” he said.

EPA’s rule is a “proper and sensible” response for the “most urgent threat that our country has ever faced,” Hostetler said.

Judge Thomas B. Griffith also expressed concern over EPA’s strategy. “It doesn’t help that the president said, ‘If Congress doesn’t act, I will,’” he said.

Judge Janice Rogers Brown asked why EPA wasn’t regulating under Clean Air Act Section 115 instead of going through “linguistic gymnastics” under Section 111(d).

No Climate Denier

clean power plan, cpp
Attorneys leave the DC Circuit Court after arguments © RTO Insider

While his questions indicated he may vote to overturn the CPP, Kavanaugh made clear he is no climate denier. He called EPA’s policy “laudable,” saying “I understand the climate is warming.”

He added that “I understand the frustration with Congress,” which has not been able to reach agreement on climate policy.

But he also expressed sympathy for coal states such as West Virginia, saying that national policy, authored by Congress, could incorporate a safety net such as public assistance and job training.

“Whole communities are going to be left behind,” he said, addressing EPA’s lawyers. “If you do it, all the people who will be left back will [remain] left back.”

It’s questionable that Kavanaugh will be able to carry a majority in overturning the rule, however. Less than a minute into Lin’s argument, Griffith interrupted to challenge his claim that the rule would be “transformative.”

He noted that EPA estimates that the amount of coal-fired generation will still be 27.4% of total generation in 2030 — only 5.4% less than projected without the rule. “That hardly sounds transformative,” Griffith said.

Judge David S. Tatel also expressed skepticism. The term “best system of emission reduction” is “an awful broad grant” from Congress, he said. “It says best system of emissions reduction,” he repeated twice, emphasizing “system.”

Emission Limit a ‘Lever’

Judges Cornelia T.L. Pillard and Patricia A. Millett also appeared sympathetic to EPA’s case.

Pillard asked how the CPP is that different from previous EPA rulemakings, which required coal-fired generators to add equipment such as scrubbers.

Peter D. Keisler, representing industry and labor challengers, said EPA failed to take into account the remaining useful life of coal plants. He insisted EPA’s authority is limited to “operation of the source” and doesn’t “extend to the investment decisions of the owner.”

“The emission limit here is a lever” to force subsidization of renewables, Keisler said. Renewables, he said, are not “sources.”

Millett asked whether EPA could force dual-fuel plants to make gas primary. Yes, Keisler responded.

clean power plan
Three judges nominated by President Obama to the D.C. Circuit Court of Appeals in 2013 are among 10 that will rule on the EPA Clean Power Plan. From left are Robert Leon Wilkins, Cornelia “Nina” Pillard and Patricia Ann Millett. Source: The White House

Judge Sri Srinivasan cited the Supreme Court’s 2011 ruling in American Electric Power v. Connecticut, which he said gave EPA a guide to how to regulate CO2 from power plants. But Srinivasan also saw a distinction between requiring coal plants to add scrubbers and requiring them to seek aid from other generators.

“The word ‘system’ is a capacious term,” responded Hostetler. He rejected opponents’ complaint that the agency was relying on a rarely invoked section of the Clean Air Act.

“You might not use a fire extinguisher until your house is burning down,” Hostetler said. “That doesn’t mean you shouldn’t use it.”

He also insisted the rule “doesn’t require any subsidies,” noting other compliance methods such as co-firing with natural gas.

Brown asked several questions but staked no clear position in the arguments. Judge Karen LeCraft Henderson said little and Judge Robert L. Wilkins was silent.

Although the D.C. Circuit’s decision is likely to be reviewed by the Supreme Court, its ruling would prevail if the high court — currently shorthanded following the death of Justice Antonin Scalia — deadlocks 4-4.

Mutually Exclusive? Section 111(d) vs. 112

One curious wrinkle in the legal questions concerning the CPP is a drafting error that resulted from the House of Representatives and Senate approving two different versions of Section 111(d) when it amended the Clean Air Act in 1990.

The section has long been used to regulate pollution from existing sources that is not covered under other sections of the CAA.

Opponents say the House’s version of the amendment barred EPA from using the section if the agency was already regulating power plant emissions under another section of the CAA. The Senate’s version, however, included no such prohibition. The two were never reconciled and President George H.W. Bush signed the revision into law with both amendments.

EPA regulates power plant emissions such as mercury, acid gases and other hazardous air pollutants (HAPs) under Section 112.

Lin said he believes the House version was the “substantive amendment” and the Senate’s was a clerical error. But he said the challengers should succeed even if the court decided to give the House and Senate versions equal weight. “The way to reconcile them … is to give both amendments maximum effect,” he said.

Judge Kavanaugh sided with the plaintiffs, saying he believed the House amendment applies.

But the other judges who spoke on the matter expressed no support for the opponents’ interpretation.

Srinivasan said that if both amendments were considered, EPA would be given the right to regulate under 111(d). “It seems like it’s inclusive and not exclusive,” he said.

Allison D. Wood, representing the non-state plaintiffs, also insisted the House exclusion should prevail. She said most, if not all, coal plants are already regulated under Section 112.

“Under your theory you can’t regulate existing sources [for CO2] at all,” responded Judge Tatel.

“I just don’t see the logic of that,” added Judge Pillard.

Justice Department attorney Amanda S. Berman said a “contextual reading is the best reading of this ambiguous text,” asking the judges to side with EPA’s “reasonable middle course.”

Adopting the House version would be a “dramatic downsizing ” of 111(d), she said.

“I don’t think Congress intended something so drastic,” she said, adding that electric generators are already regulated under “at least five sections” of the CAA.

Sean Donohue, representing environmental and public health intervenors, said the plaintiffs’ arguments were an attack on the Supreme Court’s 2007 ruling in Massachusetts v. EPA, in which the court ruled that the CAA applies to CO2 emissions from automobiles.

The court followed that up in 2011 with its ruling in American Electric Power v. Connecticut, in which the court barred common law nuisance complaints over power generators’ carbon emissions, saying it was EPA’s response to regulate the emissions under section 111(d).

Constitutional Issues

After lunch, the judges returned to hear plaintiffs’ constitutional challenge, with petitioners’ attorney David Rivkin Jr. complaining that the CPP “commandeers” state officials to implement the rule in violation of states’ rights under the separation of powers clause of the 10th Amendment.

Judges Griffith and Tatel challenged Rivkin, with Griffith asking how the CPP differed from any other federal regulation that requires state action.

Tatel, who is blind, said Rivkin’s logic would also void the Americans with Disabilities Act. Compliance with the ADA, he said, requires local governments to exercise their police powers to issue building permits for wheelchair ramps and curb cuts.

Harvard University constitutional law professor Lawrence H. Tribe supported Rivkin’s argument on behalf of the non-state petitioners. Tribe noted that the Senate had rejected cap-and-trade legislation in 2010. EPA’s supporters “are asking you to bail out Congress,” he said.

Judge Millett challenged Tribe, appearing sympathetic to EPA’s argument that rejecting the CPP would amount to a “bait and switch” after the AEP ruling.

Justice department attorney Berman called the CPP “bread and butter cooperative federalism,” saying the plaintiffs’ arguments would “take down much of the Clean Air Act.”

She said there was nothing in the record to suggest the “parade of horribles” opponents have predicted: price spikes, blackouts and jails being forced to release prisoners.

Throughout the afternoon’s arguments, only Kavanaugh consistently expressed support for the challengers. Several times, he cited the Supreme Court’s 2014 ruling in Bond v. U.S., which he said established limits to the deference granted executive agencies under Chevron. The court ruled unanimously that a woman who attempted to poison a romantic rival could not be prosecuted under Section 229 of the Chemical Weapons Convention Implementation Act of 1998. The court said there must be “a clear indication that Congress intended to reach purely local crimes before interpreting Section 229’s expansive language in a way that intrudes on the states’ police power.”

‘Notice’ Issue

Plaintiffs also complained that EPA failed to provide sufficient notice of its proposal because the final rule, issued in August 2015, included provisions not mentioned in the draft rule a year earlier.

The plan uses two different CO2 emission rates to define the best system of emission reduction, one for coal-steam and oil-steam plants and a second for natural gas plants. The draft rule had proposed a blended rate. (See Revised Clean Power Plan Allows More Time, Sets Higher Targets.)

The final rule also made significant changes in the carbon-reduction targets for some states, increasing them by 27% for Kentucky and 19% for Indiana and West Virginia. (See Final Clean Power Plan More Suited to Carbon Trading, Experts Say.)

John Campbell Barker, representing state petitioners, said EPA should be required to withdraw the rule and restart the process, as it did in withdrawing its 2012 draft rule on CO2 emissions from new electric generators.

The Justice Department’s Norman L. Rave said EPA changed the way it calculated state targets because it was “inundated” with comments objecting to state-by-state rates. Critics said the original plan would mean states that had done nothing to curb greenhouse gas emissions would have less stringent rates than those that had already taken action.

Rave said there was no shortage of opportunities to comment on the rule, noting the more than 600 meetings EPA held with stakeholders. The agency said it received more than 4.3 million comments in total.

He also cited the notice of data availability EPA issued between the draft and final rule, which signaled that it was considering factoring in states’ ability to tap out-of-state renewable resources to meet their targets. (See EPA Signals Flexibility on Interim Carbon Targets, Coal-Gas Shift.)

Rave said the petitioners had failed to clear any of the three tests needed to overturn the rule on notice grounds and had not identified any data they would have offered to EPA had they received more notice.

Record-Based Issues

The final arguments dealt with plaintiffs’ claims that EPA failed to demonstrate that its proposed compliance measures are achievable.

William Brownell, representing the non-state petitioners, said the agency failed to provide “real-world proof” that generation-shifting will work, saying the CPP envisioned “something entirely different in terms of magnitude and character” than current utility operations under least-cost security-constrained economic dispatch.

He challenged the rule’s reliance on combined cycle plants operating at 75% capacity factors, saying only 15% of them currently run that often. He also mocked EPA’s projections for the growth in wind generation, saying the agency assumed seven years of growth at the rate seen in 2012, when growth spiked because of the impending expiration of the Production Tax Credit.

clean power plan
Brett Kavanaugh is sworn in as a D.C. Circuit Court judge by Supreme Court Justice Anthony Kennedy in 2006, as his wife, Ashley, and President George W. Bush look on. Source: The White House

Millett said EPA was projecting from existing trends. “They didn’t pull these numbers out of thin air,” she said.

Wisconsin Solicitor General Misha Tseytlin said the court must determine whether the plan is achievable under the “most adverse circumstances.” That means, he said, considering the possibility that California and other states with excess renewables will “lock out” states that need them by setting onerous requirements.

“If that happens, all of EPA’s numbers break,” he said.

Justice Department attorney Brian Lynk responded that EPA was conservative in “multiple ways” in its projections, citing its assumptions on heat rates and renewable growth.

Millett asked how the agency would respond if the rule was unachievable for some states.

“I have no doubt that EPA would be amenable to consult with that state,” Lynk said. And if states were not satisfied with EPA’s response, Rave said, “I’m sure there would be an opportunity for them to come to court.”

Kevin Poloncarz, representing Calpine and other power companies supporting the rule, said the 75% capacity factor for combined cycle plants was “eminently reasonable.”

The reason such dramatic fuel switching hasn’t happened in the past, he said, is because the cost of carbon hasn’t been included in economic dispatch calculations.

EPA shouldn’t be required to take a Balkanized state-by-state approach to regulating the industry, he insisted.  “Electricity,” he said, “doesn’t observe state boundaries.”

Clark Bids Farewell to FERC at Open Meeting

By Michael Brooks

WASHINGTON — After four years, Commissioner Tony Clark’s last day at FERC will be Sept. 30, he said at his last, and 47th, open meeting Thursday.

clark bobblehead norman bay - ferc tony clark open meeting farewell
Tony Clark received parting gifts from each of his fellow commissioners, including a lookalike bobblehead from Chairman Norman Bay. Source: Norman Bay

Clark said that given the date would be the end of a week, pay period, quarter and the federal fiscal year, “this may be God’s way of telling me that that’s probably the right day to move on.”

The remaining days of his tenure will be mostly spent emptying his office, he said, though he would be available in case a quorum (a minimum of three commissioners) is needed for decisions in which another commissioner could not participate. Chairman Norman Bay recuses himself from issues he dealt with as head of the commission’s Office of Enforcement, and Commissioner Colette Honorable recuses herself from matters that were before her as a regulator in Arkansas.

Bay said he did not foresee any quorum problems following Clark’s official departure. “I feel like we’re on top of that. We’ve known for some time that Commissioner Clark would be leaving, and so we’ve been planning for the completion of any orders where his vote would be required.” Clark indicated in January that he would not seek another term.

A former North Dakota regulator, Clark is the lone Republican on the commission after the departure of Philip Moeller last year.

Clark’s three Democratic colleagues praised him for his meticulous thinking and ability to work through disagreements civilly.

“You’ve been an outstanding public servant,” Bay said. “I know that every place you’ve gone to, you have made [it] better with your thoughtfulness, your encyclopedic knowledge of policy, your reasonableness and your collegiality.”

ferc tony clark open meeting farewell
FERC Chair Norman Bay (l) and Commissioner Tony Clark before the meeting © RTO Insider

Commissioner Cheryl LaFleur joked about her disappointment at not being able to influence Clark more after he joined the commission. “From the very first day you walked in, you were always on top of the issues, crystal clear in your thinking, pragmatic and very, very decisive,” she said.

“I have enjoyed working with him very much, even though we come from different places,” Honorable said. “But in many ways, we have been quite a lot alike, I would say, in terms of … our commitment to serving.”

Honorable joked that they agreed on many things, but not on their favorite president. Her parting gift to him was a mug featuring the Democratic nominees for president and vice president, Hillary Clinton and Tim Kaine. Clark promptly hid the mug behind his name plate.

“Hopefully at FERC, people see an agency in a town that is sometimes dysfunctional, but an agency that I think is very functional,” Clark said. “Although we don’t agree on every item — that’s to be expected — … where we do disagree, we can do so without being disagreeable.”

Clark was nominated by President Obama after Sen. Mitch McConnell (R-Ky.) forwarded his name to the White House. He said he has not heard anything about Obama nominating replacements for the two GOP vacancies. He speculated that new commissioners may be among a group of nominees submitted by the next president.

The best chance for a nominee to get confirmed by the Senate would be during the lame-duck session after the November elections as part of a package of nominees, said Dan Blair, CEO of the National Academy of Public Administration, a Congressionally chartered think tank that provides advice to public officials.

But there are many different permutations of what could happen based on the results of both the presidential and senatorial elections. For example, Blair said, if Republican presidential nominee Donald Trump wins the White House, McConnell, the majority leader, could defer to him on who should go to FERC.

Many federal agencies suffer member shortages while the White House and Senate negotiate over nominations. Obama may be holding out on nominating anyone to FERC until he can reach an agreement on a Democratic nominee for a different agency, Blair said. “There’s a lot of horse trading that goes on behind the scenes. You have to look outside the commission.”

When asked if he had heard anything about reinforcements, Bay said only, “The nomination process I leave to the White House and to the Senate.”

Nicole Daigle, communications director for the Senate Energy and Natural Resources Committee, said Chairman Lisa Murkowski (R-Alaska) “is concerned that FERC will be down to three commissioners.”

“It is important that we have a full complement of members on the commission,” Daigle said in a statement.

Daigle did not respond when asked whether Murkowski had suggested anyone to McConnell or whether McConnell had forwarded any names to Obama.

A spokesman for McConnell said the senator would not comment until the president submitted a nomination. The White House did not respond to a request for comment.

Clark said he was going to take some time to relax before spending the remainder of October thinking about his next job.

FERC Considers Changes to Market Power Analyses

By Rich Heidorn Jr.

WASHINGTON — FERC said last week it is considering changing how it evaluates market power in electric utility mergers and applications for market-based rate authority (MBRA).

Most of the changes the commission is considering in its Notice of Inquiry (RM16-21) would affect merger reviews.

The commission noted that its market power evaluation for mergers, which are regulated under Section 203 of the Federal Power Act, differs from that used in MBRA applications under Section 205.

“While some of those differences may be appropriate, others may not be,” the commission said, adding that it was seeking to “harmoniz[e]” the two.

The commission asked for comment on whether it should make the following changes in Section 203 reviews:

  • Use a simplified analysis for transactions that typically don’t raise market power issues;
  • Add supply curve and market share analyses;
  • Modify how capacity under long-term power purchase agreements is attributed;
  • Require submission of documents already required by other federal antitrust regulators; and
  • Develop a more precise definition or test of de minimis in determining when a full competitive analysis screen is unnecessary in merger reviews.

The commission also is considering improving its single pivotal supplier analysis in MBRA applications and adding one to Section 203 evaluations.

Chairman Norman Bay said the proposed changes were not the result of concerns over a specific merger.

“There certainly have been a number of mergers over the last few years in the electric industry, but I don’t think there was any one specific act that led us to review the screens that we use in conducting our reviews under Section 203 of the FPA,” he said in a press conference after Thursday’s commission meeting. “I think more it’s a matter of continually striving for improvement as an organization or as an agency. And in order to do that, from time to time, you have to take a step back and examine what you’ve been doing and … ways to improve what you’re doing.”

Comments will be due 60 days after the notice’s publication in the Federal Register.

Adding Pivotal Supplier Screen

The commission said it is looking for new tools to ensure the effectiveness of its market power reviews, including the use of wholesale market share and pivotal supplier screens currently used in Section 205 MBRA reviews.

Merger applicants are currently required to perform a competitive analysis screen unless they can show that the acquisition does not increase their generation capacity in the relevant geographic markets or that the increase is de minimis.

The screen includes a delivered price test, which has been essentially unchanged since its introduction in 1996 and generally focuses on the short-term energy market “with far less detail and attention given to the other relevant products,” FERC said.

In contrast, the pivotal supplier screen measures a seller’s ability to exercise market power based on its uncommitted capacity at the time of annual peak demand in the relevant market. A seller passes the screen if wholesale load can be served without any of the seller’s capacity participating.

Although pivotal supplier tests are usually applied to energy-only markets, the commission said they could be applied to capacity and ancillary service markets under both sections 203 and 205. “Adding a pivotal supplier test to the commission’s review of a Section 203 application could make the commission’s analysis more effective because it would take into account the ability to meet demand, in addition to supply conditions, in screening for potential market power,” FERC said.

But the commission said it also seeks to improve the test because MBRA applicants “rarely fail” it.

“In many cases, the results of the pivotal supplier analysis indicate that the study area’s wholesale load can be met solely by remote suppliers, a result that is unlikely in practice,” FERC said. “The commission intended that the indicative screens would serve as a conservative threshold. However, with experience, this does not seem to be the case.”

As a result, the commission said it is considering whether to replace the current wholesale load proxy, defined as the average of the daily peak native load during the month in which the annual peak load day occurs.

FERC is considering replacing that input with the study area’s annual peak load — peak load not reduced by the proxy for native load obligation.

Market Share Analyses

The commission said its current merger analysis is a forward-looking review focused on how a transaction changes market concentration “and not an examination of market share changes or accumulation of market share over time.”

Thus, the commission said it is considering adding a market share analysis measuring the size of the applicant relative to other suppliers, allowing it to “determine if a seller has obtained a significant share in a specific market either through a series of transactions or a combination of transactions and construction, allowing for the accumulation of market power without one particular transaction triggering concerns.”

The MBRA wholesale market share screen determines whether a seller has a dominant market position by analyzing the number of megawatts of uncommitted capacity it controls relative to the uncommitted capacity of the entire market. Sellers with less than a 20% market share during all seasons pass the test.

Supply Curve Analysis

hhi-threshold-table-ferc
The Herfindahl-Hirschman Index of market power is calculated by squaring the market share of each firm competing in the market and then summing the resulting numbers. In 2012, FERC declined to adopt the 2010 Horizontal Merger Guidelines by the Department of Justice and the Federal Trade Commission, choosing to continue its reliance on the more conservative HHI thresholds in the 1992 guidelines.

The commission said it also is weighing whether to incorporate into its merger review a supply curve analysis to determine whether the acquisition would give the purchasing company the ability and incentive to exercise market power by withholding output from some generators to benefit other units and increase its overall profits.

The analysis would be more granular than the delivered price test, which measures aggregate capacity but not the breakdown by baseload, intermediate and peaking units.

“A supply curve analysis would enable the commission to identify situations that typical [Herfindahl-Hirschman Index] analyses do not capture, including situations where mergers that result in changes in market concentration below the thresholds that merit further scrutiny from an HHI perspective may still have the ability and incentive to raise prices above competitive levels,” the commission said.

Capacity Associated with Power Purchase Agreements

FERC also sees a need to change how it accounts for capacity subject to long-term firm power purchase agreements.

If a utility signs a long-term firm PPA for the output of a generating facility before filing an application to purchase that generator, the commission has usually attributed the generator’s capacity to the purchasing utility. That means the company’s acquisition of the plant would not be seen as increasing its market share.

“While the current approach of attributing the capacity of the facility to the purchaser is appropriate in the context of the market-based rate market power analysis, in the Section 203 context the change in market concentration may extend beyond the terms of the PPA,” FERC said. “For example, if a transaction conveys ownership over a generation facility where a PPA is expiring in two years, the transaction may prevent competitive supply from re-entering the market.”

Applicant Merger-Related Documents

FERC noted that merger applicants are required to submit to the Department of Justice and Federal Trade Commission both internal reports and those of consultants that concern the competitive effects of an acquisition.

“We believe these merger-related documents could be useful in the commission’s understanding of an applicant’s competitive analysis screen by providing additional information regarding, for example, the relevant geographic market definition or anticipated unit retirements,” it said.

Blanket Authorizations

FERC also is taking another look at its use of blanket authorizations — waivers of commission review for certain Section 203 transactions. The commission said it is considering canceling blanket authorizations for some types of deals and extending them to others.

“Since these blanket authorizations were granted, industry has undergone substantial change, including continued market development and expansion of RTOs/ISOs [and] consolidation among utilities, such that the conditions that gave rise to the blanket authorizations currently in effect may no longer be appropriate,” FERC said. “For example, it may no longer be appropriate to grant blanket authorizations to holding companies that only hold exempt wholesale generators, as is granted in 18 CFR 33.1(c)(8), as exempt wholesale generators now make up a significant portion of supply and any transaction involving these generators could affect wholesale rates by impacting competition.”

Exempt wholesale generators, a category created under the Energy Policy Act of 1992, are independent units that sell exclusively to wholesale customers and were exempt from some requirements of the Public Utility Holding Company Act of 1935. PUCHA was repealed in 2005.

– Michael Brooks contributed to this report.

Overheard at the NYISO Distributed Energy Resource Workshop

Jones © RTO Insider
Jones © RTO Insider

NYISO CEO Brad Jones said he is not convinced by any argument that the DER Roadmap pits the strength of a large grid against the resiliency of a small grid, as the system needs both to be robust. “Our goal is to find a way to bring both of those together to allow each of those different parts of the grid to provide efficiency for our operations and reliability for the overall grid.”

Zibelman © RTO Insider
Zibelman © RTO Insider

Audrey Zibelman, chair of the New York Public Service Commission, said, “We want the distribution markets to be optimizing distributed energy resources and optimizing load and co-optimizing that with the wholesale market, so that way will have a two-way seamless grid that is vertically coupled, that allows us to have a system that is more reliable, more dynamic, more efficient and more environmental.”

d1xzebjmqeyotbunkbdo_lyons-scottmadden-rtoinsider
Lyons © RTO Insider

Cristin Lyons, partner at consultant ScottMadden, discussed the difficulty grid operators and utilities face in gaining visibility into the volume of distributed generation and how and when it is producing. There also are questions about whether they can be aggregated and how they will be compensated, she said. “Can you verify when they’ve operated? Do you even know if they are coincident with peak? Are they dispatchable? … At the end of the day, how do all these resources get paid? I think if we’re ever able to figure out the money, everything else will follow. We’re not there yet.”

tsb0j66zsusldg1p2tfe_full_tumilowicz-epri-rtoinsider
Tumilowicz © RTO Insider

Nick Tumilowicz, who manages the Electric Power Research Institute’s DER integration effort, discussed Consolidated Edison’s Brooklyn-Queens project, which is using battery storage and distributed generation to delay construction of a $1.2 billion substation. EPRI is performing a life-cost analysis. “What does it look like when we deploy battery storage in the field … to support peak demand and efficient transmission and distribution deferral?”

00ucqzvdrkccwe9ugvoy_full_joseph-nrg-rtoinsider
Joseph © RTO Insider

Kelli Joseph, director of market and regulatory affairs for NRG Energy, considered how uncertainty in the markets currently limits how different technologies could participate. “There’s a lot of uncertainty … about what rate design they’re going to have on the distribution side. For some projects, without a wholesale participation, they probably don’t pencil out.”

mp1cnl8qioi2b2vnrorh_full_desocio-nyiso-rtoinsider
Desocio © RTO Insider

Mike DeSocio, NYISO’s senior manager of market design, devised what he said is a simple way to look at how generation assets can be classified as distributed. “If you have an asset that’s large enough to participate in the [wholesale] market today, you’re not a DER. If you have an asset that’s too small to participate in the market today and you think you’re going to need to aggregate it to participate, that’s a DER, whether it’s in front of the meter or behind the meter.”

Brattle Endorses MISO Forward Auction Proposal, Designs Demand Curve

By Amanda Durish Cook

The Brattle Group last week endorsed MISO’s proposed Competitive Retail Solution, conditioned on the RTO adopting a wider demand curve that the consulting firm developed.

Brattle Endorses MISO Forward Auction Proposal, Designs Demand Curve
© RTO Insider

Brattle’s demand curve, revealed in its latest analysis of MISO’s proposed forward auction, is capped at 140% of the net cost of new entry (CONE). The foot of the curve lands at 115% of MISO’s planning reserve margin requirement and a $0 net CONE.

Brattle said the net CONE cap is “slightly above” MISO’s requested $195/MW-day figure for Zones 4 and 7 and the $185/MW-day price elsewhere.

Brattle analyst Samuel Newell said the analysis concluded that MISO’s separate forward auction solution will address reliability concerns while inviting merchant investment. It projects volatility will be reduced by 6 to 15% compared to a status quo case Brattle researched.

Volatility

Newell said the wider curve Brattle recommends seeks to “absorb more structural volatility than other markets,” and the curve’s shift to the right is needed to accommodate a lower CONE price cap than what’s in use at other RTOs. Brattle said the curve “allows some shortage at high prices.”

He said Brattle has recommended caps ranging from 1.5 times to two times net CONE in other regions. The recommended sloped demand curve is less steep than other regions’ and extends farther to the right.

candidate-demand-curve-the-brattle-group Brattle Endorses MISO Forward Auction Proposal, Designs Demand Curve forward auction proposal competitive retail solution

“A reason to have a higher cap is to put more money in the market, and it helps protect against the risk of under-procurement if you’ve underestimated CONE,” Newell said. “Yes, the pricing is going to be volatile because of all that uncertainty that goes into the system. But as long as you have enough money built into the curve and the curve is shifted far enough right, you will attract enough megawatts.”

Brattle’s analysis predicts the new capacity structure would meet or exceed the one-day-in-10-years loss-of-load expectation (LOLE) and attract an additional 1,800 MW of merchant supply. Brattle also said the forward auction on average is predicted to clear an extra 120 MW. The analysis results will be included as testimony in MISO’s FERC filing to win approval of the forward auction.

The firm also said use of the sloped demand curve in the long run should result in average forward prices that spur merchants to build; however, Newell said the analysis didn’t forecast prices under the new auction construct. “The reason we’re here isn’t to forecast prices. It’s to address the widespread belief — that I think is right — that current prices won’t support merchant supply meeting need.”

Status Quo Falls Short

Brattle did find that in the long run, use of the demand curve under the forward design reduces the instances of auction prices clearing at the demand curve cap to 39% of years. When Brattle tested a status quo scenario in retail-choice zones, clearing at the demand curve cap amount happens 65% of the time in Zone 4 and 67% of the time in Zone 7. Brattle maintains some capacity prices clearing at the cap is needed to keep average clearing prices closer to net CONE.

Newell said Brattle tracked enough merchant supply to assume a one-in-10 standard with the curve, but MISO can also assume its utilities own supply averaging 3% more than their individual requirements. Brattle found that continuing with the status quo would result in MISO falling 891 MW short of its planning reserve margin requirement in the long term in MISO North. The status quo auction, Brattle said, also results long-term in a one-in-5.2 LOLE “with frequent severe shortage” events and a majority of auction offers clearing at the price cap.

Bill Booth of the Mississippi Public Service Commission asked if Brattle did its own analysis of MISO’s CONE value. Newell said his firm did not test the accuracy of MISO’s net CONE. But even if MISO does revise its CONE values, Newell said, results wouldn’t be affected much, as Brattle’s higher, 1.4-times CONE cap “mitigates reliability risk of administrative error in estimating net CONE.”

“This aspect is exactly the same as the one we went through for PJM and New England. This aspect of it is very established ground,” Newell said.

Newell said the bigger issue is whether Brattle’s assumptions regarding cap and foot values and utilities’ ownership is correct. Brattle analyst David Oates said a lot of the modeling, including the Monte Carlo-style analysis, is similar to what was done in PJM and ISO-NE.

MISO South

Indianapolis Power and Light’s Ted Leffler asked why MISO South was again left out of the analysis, as it was in a Brattle review released in July. (See MISO Backs Forward Auction Plan, Rejects Prompt Proposal.)

Brattle maintained the omission of MISO South was inconsequential, saying the 876 MW available for imports from the South is covered in varying megawatt amounts that utilities offer in the Monte Carlo analysis.

The company also modeled capacity import limits but not export limits and assumed utilities have a preference to build their own capacity instead of purchasing it from other utilities.

Zone 2 in Wisconsin and Michigan, which holds a small amount of participating demand, was initially included in the analysis, but Brattle found that it didn’t meet MISO’s materiality threshold.

In response to a question from Madison Gas and Electric’s Megan Wisersky, Newell said Zone 2 was initially included because it contains some competitive load. But MISO’s Mike Robinson said the inclusion was a relic of the RTO’s earlier work with Brattle and could be omitted altogether.

“It would be nice not to see that ever,” Wisersky joked.

Company Briefs

The long saga of the Duke Energy coal ash spill that coated the Dan River with up to 39 million tons of toxic coal ash from a retired coal-fired plant in February 2014 came to an end Friday when the company agreed to pay a $6 million fine to the North Carolina Department of Environmental Quality. The company already settled federal pollution violations with a $102 million settlement in 2015.

The state first fined the company a $6.8 million civil penalty, which Duke called “entirely arbitrary and capricious.” The company did not say why it was now agreeing to a fine that is only slightly lower than the original, as it agreed with the DEQ not to make any public statements that were not mutually cleared.

The two sides did say that it is “in the best interest of the parties, the environment and the citizens of North Carolina that they enter into a compromise to avoid the time and expense of prolonged litigation.”

More: Charlotte Business Journal

AEP Texas Corporate Reorganization Approved

FERC granted American Electric Power’s request that its AEP Texas North and AEP Texas Central affiliates be combined into a single organization. The companies will operate under the name AEP Texas, with AEP Utilities, an AEP subsidiary, as its direct parent.

The commission dismissed the Oklahoma Municipal Power Authority’s request that it not address FERC’s jurisdiction over AEP Texas’ wholesale transmission service, finding “no evidence that either state or federal regulation will be impaired.”

AEP told the commission it expects the organizational changes to take place by year-end.

More: EC16-135

FERC OKs Fortis Acquisition of ITC Holdings

FERC on Friday approved ITC Holdings’ acquisition by Canadian utility operator Fortis and a Singapore-based investment fund. ITC, the largest independent transmission operator in the U.S., agreed to the $11.3 billion sale in February. (See Fortis to Acquire ITC Holdings for $11.3B.)

Fortis, which owns New York’s Central Hudson Gas and Electric and Tucson Gas & Electric, is purchasing most of ITC. GIC Ventures, an affiliate of an investment company that manages the government of Singapore’s foreign reserves, is purchasing the remaining 19.9%. ITC will remain a standalone transmission company.

FERC said the transaction raised no competitive concerns because ITC does not control any generating assets, and neither Fortis nor GIC own generation or natural gas assets in MISO, home to much of ITC’s transmission network. The deal, which the companies expect to close by the end of the year, had already been approved by state regulators in Wisconsin and Missouri.

More: EC16-110, ITC Holdings

NextEra Energy’s Brady Wind Farms near Completion

nexteranexteraConstruction of NextEra Energy’s 87-turbine Brady Wind I project is 65% complete and concrete is being poured for the foundations of Brady Wind II, a nearby 72-turbine wind farm, according to the company.

Both projects are slated for completion by the end of the year. An 18.2-mile transmission line that will transmit the power to Basin Electric Power Cooperative, which signed a power purchase agreement with NextEra, will be completed in a few weeks.

More: The Dickinson Press

PG&E Appoints Eric Mullins To Company Board

PG&E last week announced the election of Eric Mullins to its board of directors and to the board of its Pacific Gas and Electric subsidiary.

Mullins is the managing director and co-CEO of Lime Rock Resources, a private equity fund specializing in the acquisition and operation of oil and natural gas properties. Before cofounding Lime Rock, Mullins worked for 15 years in the investment banking division of Goldman Sachs, where he served as managing director in the company’s energy and power group.

“As we position PG&E for continued long-term success, we welcome Eric’s expert counsel around our strategy and audit functions,” PG&E CEO Tony Earley said. “Eric’s deep financial background and familiarity with the energy sector will be invaluable assets for us.”

More: PG&E

Alliant Breaks Ground On Wisconsin Plant

Alliant Energy has started construction of a 700-MW natural gas-fired generating station near Beloit, Wis., that will combine the power plant with an adjacent solar farm in the largest paired generation station of its type in the state.

The company’s Riverside Energy Center is already home to one solar farm. The $700 million project includes a second solar installation designed to offset power used by the new gas-fired plant, company officials said. When the second solar farm is completed, there will be 8,000 panels generating solar power.

The gas-fired plant is scheduled to be in service by 2020.

More: GazetteXtra

Xcel Announces Expansion of Wind Energy in Midwest

Xcel Energy says it is planning to invest $2 billion to build eight to 10 wind farms in Minnesota, the Dakotas, Wisconsin and Michigan, with an eye toward generating about 1,500 MW of electricity.

The company said it will own and operate some of the proposed wind facilities and enter into power purchase agreements with the operators of others.

“We believe this is one of the largest wind acquisitions in the country,” said Chris Clark, president of Xcel’s Upper Midwest Operations. He said the wind farms should come online between 2017 and 2020. Xcel is looking to renewable energy — primarily wind — to offset its planned retreat from coal-fired generation.

More: Star Tribune

Dynegy Wins IPA’s MISO Zone 4 Capacity Auction

Dynegy was chosen as one of the winners of the Illinois Power Agency’s MISO Zone 4 capacity procurement auction for 2017/2018 and 2018/2019.

The company’s share of the auction was not announced, but the weighted average price was $143.20 and $137.25/MW-day, respectively. The total capacity from winning bidders was for 1389 MW for the first period and 465 MW for 2018/2019.

More: Dynegy

Great Plains Energy, Westar Shareholders OK $12.2B Deal

By Amanda Durish Cook

Shareholders voted overwhelmingly Monday to approve Great Plains Energy’s $12.2 billion acquisition of Westar Energy.

Shareholders cast their votes in separate meetings at Great Plains’ headquarters in Kansas City, Mo., and Topeka, Kan., where Westar is based. Company spokesmen said stakeholders approved all proposals necessary with at least 95% percent support.

Great Plains CEO Terry Bassham called the move “a great transaction” for stakeholders of both companies. Great Plains’ $12.2 billion offer includes $3.6 billion of Westar’s outstanding debt.

Westar CEO Mark Ruelle said the transaction would be completed next spring. Both CEOs said the acquisition will create a stronger company, with Ruelle adding that shareholder support “clearly demonstrates the value of combining Westar and Great Plains Energy.”

“The combined generation portfolio of the new utility will be more diverse and sustainable,” Bassham said. “Once this transaction is complete, more than 45% of our combined retail customer demand will be met with emission-free energy, and we will have one of the largest wind generation portfolios in the United States. This helps us maintain reliable, low-cost energy for all of the residential and business customers we serve.”

Great Plains Energy & Westar Energy combined

Westar’s 6,267 MW of generation is mostly coal-fired. Great Plains will walk away from the deal with 1.5 million customers in Kansas and Missouri, nearly 13,000 MW of generation and 10,000 miles of transmission lines.

Currently Great Plains and Westar jointly own the Wolf Creek Nuclear Generating Station and the La Cygne and Jeffrey power plants.

Westar’s shareholders will receive $60/share, paid in $51 cash and $9 in Great Plains common stock. Immediately after the vote, Westar stock was trending upward at $56.73/share.

Great Plains, parent of Kansas City Power and Light, announced plans to buy Westar in May. (See KCP&L’s Parent Great Plains Energy to Buy Westar for $12.2 Billion.)

Westar and Great Plains settled three lawsuits challenging the proposed merger, according to a U.S. Securities and Exchange Commission filing last week.

According to The Topeka Capital-Journal, a lawyer for one of the plaintiffs said the agreement will allow eight unsuccessful bidders to submit new bids. Attorney Derrick Farrell said the settlement required Westar and Great Plains to waive confidentiality provisions.

Andy Pusateri, a utilities analyst for Edward Jones, told the newspaper the settlement is unlikely to start a bidding war for Westar, saying Great Plains offered “a pretty significant premium.”

Westar also thinks the scenario is unlikely. Among other complaints, the lawsuits also alleged that the deal unfairly favored Great Plains Energy’s proposal while discouraging other and potentially better third-party bids.

“It is common to have someone file a lawsuit when mergers are announced. We were able to settle those lawsuits by simply modifying some of the language in the bidding documents. With that, the litigants agreed to stand down,” Westar wrote of the settlements.

The purchase still requires approval from the Kansas Corporation Commission, FERC, the Federal Trade Commission and the Nuclear Regulatory Commission.

The Missouri Public Service Commission wants in on the approval process, but Great Plains has said that Missouri regulators have no jurisdiction over the sale.

Westar would be the second acquisition in eight years for Great Plains, which acquired Missouri utility Aquila in 2008.

State Briefs

State Audit Reveals Faults In CPUC Contract Practices

californiapucgovThe Public Utilities Commission failed to follow state rules for awarding noncompetitive contracts, did not guard against the appearance of improper influence from utilities when making decisions and failed to fully disclose important communications, according to a new state audit.

The audit focused largely on the CPUC’s contracting methods, which showed the agency spent $2.4 million on unexplained contracts and failed to monitor performance in a third of the contracts that were reviewed.

“The shortcomings we noted in CPUC contracting practices resulted from a lax control environment that the CPUC has allowed to persist,” the auditors said.

More: Los Angeles Times

SDG&E Challenges CCA Lobbying Rules

sandiegogesdgeSan Diego Gas and Electric is challenging state rules governing the manner in which a company-backed shareholder group can lobby against the creation of community choice aggregators (CCAs).

In August, SDG&E became the first utility in the state to get approval from the Public Utilities Commission to create such a lobbying group. But the company says the commission’s framework is too onerous and exceeds what is allowable under a state law.

CCAs allow elected city officials the authority to purchase power for ratepayers instead of utilities, which still operate the distribution system. They have become increasingly popular among cities seeking to service its load entirely through renewable energy.

More: The San Diego Union-Tribune

KANSAS

Former Co-op Employee Sentenced for Embezzlement

sedgewickcountycoopsedgewickcountyA former Sedgwick County Electric Cooperative employee was sentenced to five years’ probation for embezzling thousands from the co-op.

Jamie L. Martin, 48, was ordered to repay the co-op about $187,000 and another $97,000 to cover the costs of the audit that uncovered the theft. She could serve 22 months in prison if she fails to abide by the terms of her probation.

Martin pocketed cash payments from customers, altering computer records to conceal the losses.

More: The Wichita Eagle

MICHIGAN

Bill Would Prevent Customers From Paying for Leaked Gas

michiganrepjeffirwingov
Irwin

State Rep. Jeff Irwin (D-Ann Arbor) has introduced legislation that would block utilities from charging customers for gas that leaks from their systems before it can be sold.

Irwin said he was inspired to draft House Bill 5913 after he read a recent economic analysis that concluded utilities are less motivated to fix gas leaks when they can recover the cost of leaked gas in rates. “The public should not be subsidizing gas leaks,” Irwin said in a statement. “Charging customers for gas that they never get picks their pockets and pollutes the environment.”

Consumers Energy spokesman Dan Bishop said his utility was reviewing the bill. Bishop also called the wasted gas issue a de minimis problem, meaning it didn’t merit consideration.

More: MLive

NEW MEXICO

Albuquerque Approves Resolution for 25% Solar

albuquerqueenergycouncilgovThe Albuquerque City Council unanimously approved a resolution that aims to power city-owned buildings and facilities 25% through solar energy by 2025.

The city’s Energy Conservation Council will put together a plan for the mayor and council with implementation options and recommendations to reach the 25% goal.

More: Albuquerque Business First

OHIO

New Natural Gas-Fired Plant Approved by Siting Board

ohiopowersitingboardgovThe Power Siting Board has approved plans from Advanced Power Services to build a $1.1 billion, 1,105-MW natural gas-fired power plant in Columbiana County. The location will give the plant direct access to the region’s shale gas resources.

Construction is set to begin in January, and the plant should be operational by 2020. The plant will replace about a fifth of the capacity that American Electric Power sold off in a deal announced last week.

More: Columbus Business First

RHODE ISLAND

Town Council Opposes Invenergy Power Plant

burrillvillepowerplantclearriverThe Burrillville Town Council voted unanimously to oppose the construction of a 1,000-MW natural gas power plant, ending its official silence on the controversial $700 million Invenergy project.

The council voted at a special meeting held in a high school auditorium to accommodate larger-than-usual attendance. Members said they took the stance only last week so as not to unduly influence the boards and commissions that had been asked to submit advisory opinions on the Clear River Energy Center, which would be located in woodlands near the town.

The town had told the state’s Energy Facility Siting Board that Invenergy’s application was incomplete. Additionally, local authorities that were counted on to provide cooling water for the plant have withdrawn agreements to do so. (See Proposed RI Power Plant Loses Cooling Water Source, Seeks Delay.)

More: Providence Journal

VIRGINIA

State Approves Dominion’s Coal Ash Wastewater Plan

The State Water Control Board approved Dominion Virginia Power’s plan to treat the millions of gallons of coal ash wastewater stored in ponds and discharge it into the James River.

Dominion said that after the wastewater has been treated and discharged, it will no longer use wastewater ponds to store coal ash and will switch to a dry storage method in which the ash will be transferred to lined landfills.

The approval came over the objections of environmental groups. “We are just disappointed that the board did not take steps to further improve the permit,” said an attorney with the Southern Environmental Law Center.

More: Richmond Times-Dispatch

ISO-NE Outlines Keene Road Tx Upgrade Study

WESTBOROUGH, Mass. — ISO-NE planners last week outlined the scope of a needs analysis that will determine whether the RTO will approve transmission upgrades to accommodate wind development in the Keene Road area in Maine.

detail of keene road export constrained area iso ne - ISO-NE Outlines Keene Road Transmission Upgrade Study

An economic study found that the area could qualify for market efficiency transmission upgrades (METUs) — projects designed to reduce the total production cost to supply system load.

At Wednesday’s Planning Advisory Committee meeting, planners said the needs assessment will simulate production costs with the Keene Road export limit modeled at the existing 165-MW limit and three higher limits that top out at 255 MW.

The modeling will provide results for 2020, the projected in-service date for the upgrades, as well as 2025 and 2030. In addition to production costs, the simulations will predict metrics such as congestion, emissions and LMPs at several locations.

Draft results are expected to be brought to the PAC for stakeholder discussion by November, with final results posted in December. If the results show the upgrades qualify as METUs, the RTO could decide to issue a competitive solicitation.

A draft study in 2015 found that increasing the export limit to 225 MW could save $1.4 million to $5.7 million in production costs annually by allowing additional wind development in the area and displacing more expensive hydropower. (See “Draft Study Shows Greater Wind Penetration Benefits,” ISO-NE Planning Advisory Committee Briefs.)

– William Opalka

Texas PUC OKs ERCOT, SPP Studies on Lubbock Move

By Tom Kleckner

Texas regulators last week accepted a proposal from ERCOT and SPP staff on how they will coordinate their separate studies on Lubbock Power & Light’s planned move to the ERCOT grid.

In a joint letter to the Public Utility Commission of Texas, Warren Lasher, ERCOT’s director of system planning, and Lanny Nickell, SPP’s vice president of engineering, said their studies will use “consistent input assumptions” and “rely as much as possible upon their existing study processes” (Docket No. 45633).

lubbock power & Light service territory (puct, spp, ercot)

SPP said it will use models from its most recent Integrated Transmission Planning Near-Term (ITPNT) assessment and its 10-year ITP study. ERCOT will use models from its most recent Regional Transmission Plan and its Long-Term System Assessment.

Both RTOs will also conduct near-term reliability studies and longer-term economic studies. “Both parties will analyze their systems with and without the portion of LP&L that is part of the proposed transition,” Lasher and Nickell wrote.

LP&L announced last September it planned to disconnect 430 MW of its load from SPP and join ERCOT in June 2019. An ERCOT study completed in June indicated it will cost $364 million and take 141 miles of new 345-kV rights of way to incorporate LP&L into ERCOT. (See “LP&L Integration Could Unlock More Panhandle Wind Energy,” ERCOT Board of Directors Briefs.)

At a meeting Thursday, PUC Chair Donna Nelson said she agreed with the grid operators’ approach, but she expressed concern over who would pay for the studies. “Either LP&L should fund the studies, or we should leave the issue open pending the outcome of the studies,” Nelson said. “I don’t think it’s fair for the ratepayers in ERCOT to pay for that study.”

ERCOT and SPP said they had not come to a conclusion on funding the studies, but they would discuss with the commission “the appropriate allocation of the costs.”

ERCOT said it could complete its assessments before the end of the year, while SPP said it would complete its 2017 ITP10 in January and the 2017 ITPNT in April.

The grid operators said they would be unable to provide two pieces of information that Nelson requested in a July memo. (See PUCT Asks ERCOT, SPP to Coordinate on Lubbock P&L Move.)

Lasher and Nickell wrote their staff does not have “the expertise or the necessary data” to determine the cost and reliability impacts as separated by customer class. They also deferred to LP&L “to describe measures necessary to ensure that there will be no commingling of electrical energy from the two regions as a result of the proposed transfer.”

At the same time, LP&L is conducting its own study. The utility’s attorney, Chris Brewster, asked the PUC to request ERCOT and SPP disclose their assumptions “to ensure we’re talking about the same things.” LP&L said it had had discussions with ERCOT, but not with SPP, and questioned the latter’s “scheduling constraints.”

“I don’t know what their scheduling constraints are, but they have a lot of employees. They have a lot of smart employees,” Nelson said, pointing out Nickell and SPP attorney Sam Loudenslager’s presence in the audience. “It’s in their best interest that ratepayers don’t end up paying for being unfairly advantaged when Lubbock leaves.”

Any PUC rulemakings will wait until the results are all in next year.

“We want to make sure we can get it right,” Nelson said. “We have people concerned about costs within the SPP system, and we have people concerned about costs in the ERCOT system. Clearly, we ought to be concerned about that.”