Search
`
November 17, 2024

Company Briefs

fortcalhoun(nrc)The Omaha Public Power District’s board voted unanimously to close the 479-MW Fort Calhoun nuclear plant by the end of the year. The closure of the plant, the country’s smallest nuclear facility, affects 700 employees and will lead to a decommissioning effort expected to cost $1.2 billion.

The vote came after management reported that it cost the utility about $71/MWh to generate power at the plant, double the national industry average. The utility can purchase power on the open market for about $20/MWh.

The utility has sunk nearly $700 million into Fort Calhoun over the past decade for upgrades, flood repairs and to extend the plant’s license to 2033. The plant was commissioned in 1973.

More: Omaha World-Herald

Oil Firm Files Lawsuit Over Kemper Delay

kemper(wiki)Oil exploration firm Treetop Midstream Services sued Southern Co. over the tardy Kemper coal-gasification plant in eastern Mississippi, from which Treetop was committed to buy carbon dioxide to stimulate depleted oil fields.

Treetop is seeking $100 million and punitive damages from Southern, claiming that the utility committed fraud by misleading it on the construction timeline. The Kemper power plant is more than two years behind schedule and is now expected to be operational in the third quarter of this year.

Treetop had signed a contract for 30% of Kemper’s CO2 output to pump into oil fields to tap supplies previously considered uneconomic. The company spent nearly $100 million to construct a CO2 pipeline linking Kemper and its oil-producing area. The plant’s operator, Southern subsidiary Mississippi Power, canceled the Treetop contract earlier this month.

More: Watchdog.org

Consumers Opens 1st Solar Garden on Campus

Consumers Energy has opened its first solar power plant on the campus of Grand Valley State University in Western Michigan. The facility is a 3-MW array that is also the state’s largest community solar project.

The 17-acre Solar Gardens includes Michigan-made solar panels. “This new Solar Gardens location illustrates our commitment to finding new approaches that will sustain our state for generations to come,” Consumers CEO John Russell said.

The company is expecting to open a similar solar garden site about 60 miles away at Western Michigan University later this summer.

More: Consumers Energy

AEP Wins Award for Reconductor Project

aepreconductoring(aep)American Electric Power won the Edison Electric Institute’s highest award for a project in Texas where it upgraded two 345-kV transmission lines without taking them out of service.

The Energized Reconductor Project in the Lower Rio Grande Valley of Texas incorporated robotic equipment and “energized barehand” work methods, in which the linemen wear conductive suits and come in contact with live wires. Working with contractors Quanta Services and CTC Global, AEP was able to replace 240 miles of line while they remained energized, negating the need for alternate generation during the project. AEP estimated it saved more than $43 million.

“Traditional construction methods would have required taking those lines out of service, but AEP developed an innovative technical solution that permitted the company to successfully upgrade the system while maintaining service and reliability,” said EEI President Tom Kuhn in presenting the company with its 2016 Edison Award.

More: Edison Electric Institute

Lincoln Rejects Request to Disclose Pricing Information

askamit(askamit)Lincoln Electric System says it will stop publishing breakdowns for the cost of generating electricity at specific facilities in the wake of demand by a wind energy producer to see its financial books.

Gary Aksamit, the head wind power developer Aksamit Resource Management, earlier this year demanded the state’s four largest public power entities disclose their generation costs. The utilities say they gave him thousands of pages of documentation but that revealing certain data would put them at a competitive disadvantage.

LES has historically sold power directly to end users and published details on its generation costs. With SPP’s 2014 implementation of the Integrated Marketplace, the utility now buys and sells electricity in competition with other regional power suppliers.

More: Lincoln Journal Star

Orion Renewable Eyes 250-MW Wind Farm in North Dakota

orionenergy(orion)The Orion Renewable Energy Group says it is planning a 115-turbine wind farm in western North Dakota, capable of generating 250 MW.

The California company has not filed a conditional use permit with county officials, but it said it has completed most of its land leasing and environmental studies. If Orion receives county approval, it will file an application with the state’s Public Service Commission by the end of the year.

More: The Dickinson Press

LG&E-KU Begins Commercial Solar Building Program

lgeku(lgeku)Louisville Gas & Electric and Kentucky Utilities launched a new business solar service in which the utilities will construct, own and operate individual solar facilities for commercial and industrial customers.

The ground or rooftop solar arrays ranging from 30 kW to 5 MW will be built on customer property by Kentucky-based Solar Energy Solutions.

“Providing regulated distributed generation through this new customized business solar service will be a new venture for us, but we expect this to be responsive to our customers’ needs,” said John P. Malloy, vice president of LG&E and KU Energy customer service.

More: SurfKY News

Company Proposes 100-MW Solar Farm in Va. Tidewater

communityenergysolar(community)Community Energy Solar has filed preliminary applications to develop a 100-MW, 1,200-acre solar farm near the towns of Boykins and Newsoms in Virginia’s Tidewater region. The company said it plans to begin construction of the $175 million Southampton Solar project by the end of 2017.

The company has developed about 1,400 MW of solar in 13 states since 1999 and is building an 80-MW facility in Accomack County, Va., which is expected to come online by the end of this year.

The company’s latest plans were filed with Southampton County, and it will need approval from PJM, the state Department of Environmental Quality and various other regulatory agencies before going forward.

More: The Tidewater News

Seattle Company Applies to Build Floating Wind Farm

tridentwindscalifornia(trident)Trident Winds applied to build a wind farm off the coast of California in which the wind turbines will be mounted on tethered, floating pylons much like offshore oil drilling rigs, rather than bolted to the sea floor like other proposed offshore U.S. wind projects.

The company wants to construct 100 636-foot floating turbines about 15 miles off the coast of Morro Bay. When completed, the facility would generate up to 1 GW. If it is approved, it would be the largest offshore wind project in the nation.

Because of the technological challenges, the project isn’t expected to go online until 2025.

More: The San Diego Union Tribune; The Mercury News

CAISO Study Would ID Gas Generators Vulnerable to Early Retirement

By Robert Mullin

Concerned that large numbers of gas-fired generators will retire early because of competition from lower-cost renewables, CAISO last week proposed a study to identify the most vulnerable units in its balancing area.

The initiative to gauge the risk of “economically driven” retirements is a result of California’s 50% by 2030 renewable portfolio standard, enacted last year.

That mandate — along with other state and federal environmental measures — is expected to increasingly leave nonrenewable resources at the margins of the ISO’s wholesale markets, reducing the income stream for gas generators already dealing with depressed power prices.

Transmission planners would use the study’s findings to assess how potential gas retirements would affect reliability and congestion in ISO load pockets, including local capacity requirements (LCR) areas — regions with increased resource adequacy requirements based on limited import capability. The ISO’s largest metropolitan areas — the Los Angeles Basin, San Diego and the San Francisco Bay Area — are all LCR areas.

ISO staff said the study will not evaluate the impact of gas retirements on overall system resource adequacy, instead limiting its focus to local impacts.

“We’ll go through all the LCR areas one by one,” said Yi Zhang, CAISO regional transmission engineer lead, during a June 13 conference call to discuss the study with stakeholders.

The ISO will accept comments on the proposed study — including its necessity — until June 27.

Study results are intended to inform the ISO’s 2016-2017 transmission planning cycle and the long-term planning process.

The study would screen for potential gas retirements by first overlaying the ISO’s 2015-2016 production cost models — the framework for determining the most cost-efficient generation configuration for serving load — with expected portfolio changes stemming from the 50% renewables mandate. The latest LCR results would also be factored into the assessment.

Based on that information, CAISO would apply three criteria to identify whether a gas unit exhibits a high potential for early retirement:

  • A capacity factor below the typical value for the type of generator;
  • No revenue from ancillary services; and
  • Not required to meet LCR.

A unit meeting the first two criteria, but also needed to meet LCR in a designated area, would likely avoid retirement — except in LCRs with surplus generation.

“If one area has a surplus, there may be some risk of early retirement,” Zhang said.

Calpine Vice President Mark Smith questioned the soundness of CAISO’s criteria for determining the financial viability of units deemed vulnerable.

“You know retirement is fundamentally an economic decision [for generating companies],” Smith said. “Why aren’t you using financial information to assess this rather than the criteria you’ve chosen?”

He contended it would “a very, very dangerous assumption” that any units will be compensated to “stay around.”

Calpine earlier this year idled its gas-fired Sutter Energy Center in Northern California, saying the plant was not economically viable. In 2012, the California Public Utilities Commission directed the state’s three investor-owned utilities to enter into contracts with the 578-MW, combined cycle plant to keep it operating for reliability reasons, but those agreements expired later that year. The PUC has resisted the idea of California developing a capacity market — or any system of capacity payments — to keep such plants available.

sutter energy center (calpine), CAISO, gas generators
Calpine idled its gas-fired Sutter Energy Center in Yuba City, California earlier this year for econmic reasons. Source: Calpine

“Trying to do a bottom-up analysis of individual units and trying to understand the value chains they have access to is a far broader exercise,” replied Neil Millar, CAISO executive director of infrastructure development.

“This is our first time to take on this analysis and our focus is the risk to the grid,” Millar said, adding that the ISO will refine its approach in the future.

Zhang said CAISO plans to share a list of potential retirements during a September stakeholder meeting.

Cathey’s Inner Geek Helps SPP Incorporate New Technologies

By Tom Kleckner

LITTLE ROCK, Ark. — It doesn’t take much for SPP’s Casey Cathey to let his inner geek flag fly.

Casey Cathey, SPP (copyright RTO Insider)
Casey Cathey, SPP © RTO Insider

“Have you heard about Solar Reserve’s salt tower?” he asks, jumping to his feet and grabbing a marker. Cathey steps to the whiteboard and begins to sketch a representation of the 110-MW Crescent Dunes Solar Energy Plant in Nevada. It is capable, its developers say, of providing enough firm solar energy to power 75,000 homes.

Cathey explains how the 10,000 tracking mirrors encircle the 640-foot molten salt tower, following the sun’s movements to concentrate sunlight onto a large receiver at the top of the tower. Molten salt flows through the receiver and down piping inside the tower, eventually being stored in a thermal tank. The salt is then passed through a steam-generation system that provides electricity as needed.

“I’m sorry, but I really geek out about things like this,” a visibly excited Cathey says.

It comes with the job. As manager of operations analysis and support, Cathey led the group that produced a 2015 wind-integration study that revealed SPP could successfully handle wind-integration levels as high as 60%. That same group is now working on a follow-up analysis, the newly renamed Variable Generation Integrated Study.

Cathey also represents SPP on the ISO/RTO Council’s Emerging Technologies Task Force, which has further exposed him to the new technologies and challenges facing the electric industry.

“What we’ve learned is everyone has problems,” he says. CAISO “has too much solar; we have a lot of wind; [and] Toronto has reduced their nuclear plants to offset the wind.”

Front-Row Seat

Cathey almost can’t believe his luck at having a front-row seat to the latest in technological innovation.

“It’s pretty amazing, especially with the people I get to meet and talk to. Ph.D.s, Popular Science, Elon Musk,” he says. “I used to put that stuff on a pedestal, but then you get to meet them and see where we’re at and where we’re going, and you start to realize where the human race is in terms of technology.

“There are a lot of brilliant people out there, but at the same time, there’s a lot of things we can do better,” he added. “There’s a lot of stuff we can improve on.”

For now, Cathey and SPP are working to educate themselves on wind and solar energy, behind-the-meter resources, and batteries, flywheels and other energy storage technologies. The more staff knows, Cathey says, the better they can forecast.

What’s Out There?

“We’re focused on our current business functions as a balancing authority and market reliability. It’s starting to be a little worrisome that we don’t know what’s out there, and we don’t have rules in place to report it.”

Cathey says SPP currently has a requirement that any behind-the-meter resource capable of producing 10 MW or more has to register in the Integrated Marketplace, so it can be modeled correctly. He says loopholes in the requirement allow for derating resources or splitting them up, saying the ratings of some resources do not always tell the whole story.

“The worst risk is if there are many smaller facilities we don’t know about, we could potentially coordinate outages incorrectly and we would not know the real impacts on the Bulk Electric System,” he says. “At these small magnitudes, they’re not going to bring down the system, but if we don’t know about certain generation and we’re not coordinating it, we could have a problem with efficiency and reliability.

“We understand the capabilities and types of generation out there, but … we’re pretty much in the same boat as a lot of other ISOs and RTOs. We don’t know what we don’t know, and [other RTOs] don’t know. The loads themselves don’t know.”

To get better information, SPP has surveyed its members about their behind-the-meter resources.

The RTO hasn’t yet settled on a name for the resources. MISO calls them DERs (distributed energy resources) while ERCOT refers to them as DG (distributed generation). And SPP?

“We don’t have a term yet, but I’m sure it’ll be a different acronym when we come up with it,” Cathey says with a laugh. “Right now, we just want to know about it, so that our models are accurate.”

The RTO will eventually require more stringent reporting on distributed generation, Cathey says — and despite some stakeholder fears, the requirement will not force them to register the resources in the market or to inhibit their contributions to state renewable portfolio standards.

SPP does have an acronym for stored energy resources: SERs. Staff has drafted a revision request that would add energy storage capability to the Integrated Marketplace’s rules, enabling the resource to be registered as a generator type for regulation only. Staff has tweaked the revision request to take advantage of PJM‘s and MISO’s experience with the technology.

Cathey says SPP’s current rules are not “conducive to allow us to embrace that technology.”

“You can actually help out the system by plugging [the batteries] in … they’re providing regulation-down service,” says Cathey, who expects the first SER to show up by year-end. “That extends the life of conventional resources, because we’re not [ramping] them up and down. We’re sending the battery up and down.”

SPP’s current wind-integration study was renamed to include technologies like these, but its primary focus remains wind. The RTO has already seen wind integration reach 48.32%, a record for all North American ISOs and RTOs. It currently has 12,397 MW of installed and available wind capacity, with another 33,819 MW in development.

cathey, spp

Cathey says the current study, which will use updated models and assumptions to analyze frequency response and transient response, is an extension of the 2015 study. It will take a “much more thorough” look at voltage, he said. The first study ignored thermal constraints and used an hourly ramp, but the second study will honor thermal ratings and use a five-minute ramp, “so it’s much more realistic.”

“Frequency and ramp, that’s one aspect we’re really interested in,” he says. “Is there a real problem when we have 50%, 60% wind penetration, while honoring thermal constraints? Are we Chicken Little, or is this an actual problem?”

SPP is working with Powertech Labs to develop a module that honors thermal constraints and is placed on top of its voltage-security assessment tool. Cathey says the RTO is past the R&D phase with the technology, which will eventually be rolled out to other ISO/RTOs.

“The model basically … lets us know we need to concentrate further on [a] scenario and build in more planning and operational processes,” he says.

Data, Data and More Data.

Cathey is also helping out with SPP’s Synchrophasor Strike Team’s work, which is intended to ensure the RTO isn’t pushing phasor measurement units (PMU) without stakeholder buy-in.

PMUs are devices that measure the voltage, frequency and angle of the grid’s electrical waves, using a common time source for synchronization. The devices can take samples hundreds of times a second, while the standard SCADA systems can have scan rates of 10 to 30 seconds.

“If we’re making measurements at that scale, we can determine whether there are issues with the models,” Cathey says. “But the problem with PMU incorporation is the data is so much. An operator needs to understand if it’s just a blip on the system for a nano-second. You’re talking petabytes [1 million gigabytes] of data. You’re well beyond terabytes.”

Staff is currently working on how best to filter the data and make it more manageable for operators. In the meantime, SPP has posted a revision request that would require all new generators to have a PMU. The request has been vetted within the strike force, which will determine whether the cost-benefit analysis justifies requiring existing generation to be retrofitted with PMUs.

Oklahoma Gas & Electric, which has installed more than 200 PMUs as part of a Department of Energy grant, has become a proponent of the technology, Cathey said.

“They’re the [subject-matter experts] for the industry, not just our area,” he says. “According to OG&E, the cost is not that much. Where the cost comes into play is if your substation or your switchyard is not capable of accepting the PMU.

“These are things we don’t traditionally think about. We think about power, getting it from Point A to Point B and whether the line can sustain it. … Now, we’re thinking about very engineering-centric problems.”

Which is exactly the way Cathey likes it.

FERC Accepts ISO-NE Auction Results

By William Opalka

FERC accepted the results of ISO-NE’s 10th Forward Capacity Auction last week, again rejecting allegations of market manipulation and concluding that the prices were just and reasonable (ER16-1041).

Brayton Point power plant, ISO-NE forward capacity auction, ferc
Brayton Point Wikipedia

The auction, covering the 2019/20 commitment period, saw prices drop to $7.03/kW-month from last year’s $9.55/kW-month. It was the first decline in four years. (See Prices Down 26% in ISO-NE Capacity Auction.)

The Utility Workers Union of America has claimed the Brayton Point generating plant in Massachusetts has been withheld from the last three auctions to drive up capacity prices. The plant, purchased by Dynegy in 2015 from Energy Capital Partners, is scheduled to close next year. (See FERC Again Rebuffs Brayton Point Union.)

“We emphasize, as the commission has stated in previous orders, that the commission’s Office of Enforcement reviewed Brayton Point’s bidding behavior in FCA 8 to determine whether further investigation of Brayton Point was warranted and ‘found credible justifications for the owners’ retirement decision and elected not to widen its investigation to include Brayton Point,’” FERC said. “We are not persuaded by Utility Workers Union’s allegations that market manipulation affected FCA 10, as the record is devoid of any evidence to that effect, and we similarly reject Utility Workers Union’s request for a stay pending discovery and further adjudication of that allegation.”

The commission also said that a “rigorous” review by ISO-NE’s Internal Market Monitor determined FCA 10 was competitive.

FERC Backs ISO-NE in Tariff Dispute

In a separate order, the commission rejected a complaint that alleged ISO-NE violated its Tariff when it refused to qualify an increase in a Massachusetts generating plant’s output for FCA 10 (EL16-48).

Northeast Energy Associates, owner of the Bellingham generating station, agreed with ISO-NE that an additional 10 MW of capacity was a “significant increase” but disagreed on whether it should be treated as new or existing capacity. New capacity is required to submit a composite offer linking incremental summer qualified capacity to existing winter qualified capacity.

NEA said the 10 MW should have been added to the existing summer qualified capacity without a composite offer and asked the commission to order ISO-NE to include the increase as if it had cleared FCA 10 — a move that would result in capacity payments to NEA of almost $844,000.

FERC sided with ISO-NE, saying that NEA, which is owned by subsidiaries of NextEra Energy and GDF SUEZ Energy Resources, misread the Tariff.

“We agree with ISO-NE that … the Tariff is clear that a significant increase must abide by all the provisions applicable to a new generating capacity resource,” FERC wrote.

This is the second time FERC has addressed a capacity increase for Bellingham. Previously, FERC granted a waiver to allow the plant to participate when the company submitted a late interconnection deposit. ISO-NE wanted to disqualify the resource, but the commission said a good-faith effort was made to submit a timely payment after NEA discovered its oversight. (See FERC Overrides ISO-NE, Grants Waiver for Late Capacity Payment.)

FERC Proposes Protections on CEII

By Michael Brooks

WASHINGTON — FERC last week issued a Notice of Proposed Rulemaking to implement legislation enacted last year to protect the grid from terrorist attacks (RM16-15).

The Fixing America’s Surface Transportation (FAST) Act, signed by President Obama in December, was mainly a highway funding bill, but it also amended the Federal Power Act to require FERC to update its critical energy infrastructure information (CEII) regulations. (See Transportation Bill Includes Grid Security Measures.)

The NOPR details how the commission plans to update its procedures for designating CEII, sharing CEII with other government agencies and sanctioning employees for unauthorized disclosures.

“Obviously, maintaining the confidentiality of critical infrastructure information is absolutely essential to our work in this area, particularly on reliability,” Commissioner Cheryl LaFleur said. “The FAST Act contains important new authority for the commission that allows us to both protect critical information and confidentially share it with government and private parties.”

LaFleur in particular praised Congress’ exemption of CEII from Freedom of Information Act disclosure.

The sanctions for unauthorized release of CEII stemmed from former Chairman Jon Wellinghoff publicly discussing a confidential FERC analysis on the grid vulnerability to physical attacks. The NOPR says that any FERC employee who knowingly discloses CEII would be subject to termination and/or criminal prosecution. Commissioners who do so would be referred to the Energy Department’s Inspector General.

FERC Chairman Norman Bay would not detail what criminal statutes an employee would be prosecuted under, only saying that CEII is not the same as classified material.

Comments on the NOPR are due 45 days after its publication in the Federal Register.

NERC Databases

FERC also amended its regulations to require NERC to provide the commission and staff access to three of its databases (RM15-25).

The rule gives FERC access to NERC’s transmission availability data system, generating availability data system and protection system misoperations databases. (See FERC to Look over NERC’s Shoulders on Reliability.) It will not take effect, however, until the commission issues a final order implementing the FAST Act provisions.

New York Transmission Developers Ask FERC to Order a Do-over

By William Opalka

Three competitive transmission developers asked FERC last week to order NYISO to issue a new request for proposals for transmission upgrades to alleviate congestion and bring renewable energy downstate (EL16-84).

The RFP was issued in February in response to a New York Public Service Commission order that declared a public policy need for two projects in the Mohawk and Hudson valleys to deliver energy to load centers in and around New York City. (See NYPSC Directs NYISO to Seek Tx Bids.)

The developers — Boundless Energy NE, CityGreen Transmission and Miller Bros. — say NYISO violated its Tariff and FERC directives under Order 1000 when it solicited projects without conducting its own review and instead deferred to state regulators.

“We are filing a petition with FERC because the NYISO violated its FERC tariff by inappropriately deferring to the New York Public Service Commission rather than follow its FERC-approved transmission planning function,” Boundless President Rod Lenfest said in a statement.

nypsc

“Based on FERC’s own guidelines, the NYPSC has a limited role in the energy transmission planning process. While that planning process allows the NYPSC to identify to the NYISO the transmission needs for the state, here the NYPSC went even further and pushed for a particular project solution to meet those needs. Rather than consider these projects along with other alternatives that could reduce costs for consumers, the NYISO decided to consider only proposals for the particular projects identified by the NYPSC.”

The developers asked FERC “to confirm that the NYISO, not the NYPSC, is the entity that is required to study and identify the specific project solutions.”

The plaintiffs said the ISO should follow its normal study process — including its base assumptions and generator dispatch modeling — to consider competing solutions without excluding specific technologies or relying on the PSC’s assumptions and modeling.

Developers’ proposals, which were submitted in late April, are currently being evaluated by NYISO staff.

Boundless CEO E. John Tompkins said in an affidavit that the company is seeking a stay of the solicitation process in the appellate division of the state Supreme Court.

The company participated in an evaluation of potential projects last year by NYPSC staff in its AC Transmission initiative. But staff recommended that the developer be disqualified because its proposals were deemed to be not cost-effective. (See NYPSC Staff Recommends $1.2B in Transmission Projects.) Boundless also sought a rehearing of the NYPSC order that declared the public policy need, but that petition was denied in February.

Earlier this month, NYISO named 10 project finalists in a concurrent public policy proceeding designed to alleviate congestion in the Buffalo area. (See NYISO Identifies 10 Public Policy Tx Projects.)

FERC Eliminates Wind’s Reactive Power Exemption

By Michael Brooks

WASHINGTON — New wind generators will be required to provide reactive power following a FERC order last week eliminating their exemption from having to provide the service (RM16-1).

wind inverter reactive power ferc
Inverters, necessary for wind turbines to provide reactive power, have become much less expensive since FERC exempted the resource from having to provide the service.

Reactive power, essential for controlling the voltage of the grid, can be measured at three points: the generator itself, the generator substation or the point of interconnection. Synchronous generators’ reactive power is measured at the interconnection point.

The commission’s order revises the commission’s pro forma generator interconnection agreements — both small and large — to require nonsynchronous generators’ reactor power to be measured at the high side of generator substations. In its Notice of Proposed Rulemaking in November, FERC had proposed the interconnection point, but it was persuaded by commenters who said doing so would require additional investment in equipment.

FERC issued the wind exemption in Order 661 in 2005 because it was concerned that the cost of the technology needed to provide reactive power would inhibit the development of the resource. Improvements in that technology since then have made it far less expensive, and FERC said that continuing the exemption could result in insufficient reactive power as wind power grows and traditional synchronous generation retires.

Order 661 did not exempt other types of nonsynchronous generation, such solar, but FERC has been treating them similarly to wind on a case-by-case basis. The commission has sometimes required that balancing authorities demonstrate that the lack of reactive power from a non-wind, nonsynchronous generator would threaten reliability before requiring it to provide the service.

The new requirements apply to all new nonsynchronous generators, regardless of type, that have not executed a facilities study agreement as of 90 days after publication in the Federal Register. They would not apply to existing generators, including those making upgrades that require new interconnection requests. FERC said these provisions would allow generators to complete the interconnection process without delay or extra costs.

FERC approved the new requirements at Thursday’s meeting, which was open to the public again after the commission closed it last month. (See Pipeline Protesters Force FERC to Close Monthly Meeting.) Staff’s presentation of the order was interrupted by two protesters, who urged the commission to halt approval of natural gas pipelines.

“There’s a certain irony here because the protesters interrupted a presentation by staff on commission work that can enable a higher degree of penetration by wind resources while maintaining reliability,” Chairman Norman Bay said in response. “This final rule will ensure comparable and nondiscriminatory treatment of both traditional resources and new resources, such as wind and solar, in the provision of reactive power, while recognizing that some technological differences remain.”

“Today’s rule recognizes that wind and other nonsynchronous generators, which are an increasingly important part of the fleet, now have the technical ability to provide reactive power at reasonable cost, and so they’ll now be required to do so,” Commissioner Cheryl LaFleur said. “I think today’s rule highlights that wind and solar are no longer just niche technologies.”

FERC OKs Change to MISO SSR Process

FERC last week accepted portions of MISO’s system support resource (SSR) Tariff changes but rejected the RTO’s proposal regarding the retention and transfer of interconnection rights (ER12-2302-004).
The changes allow new generation not available at the time of reliability studies and SSR designation to become an alternative to an SSR assignment.

However, FERC told MISO its proposal on interconnection rights had gaps.

Presque Isle Power Plant (Source We Energies) - FERC MISO SSR process interconnection rights
Presque Isle Power Plant Source: We Energies

MISO permits owners and operators of retiring SSR facilities to retain or transfer interconnection service. FERC said that in three filings, the RTO hasn’t yet proposed an impartial method for implementing the rule.

“MISO must propose additional procedures that ensure that the retention and transfer of interconnection service is offered on a fair, transparent and nondiscriminatory basis,” FERC said. “MISO is required to propose additional procedures, which should, among other things, allow a clear and consistent way in which generators seeking a transfer of interconnection service from a retiring generator may identify opportunities and address how such a generator would be chosen for such service.”

FERC also said MISO’s February filing to remove language regarding retention of interconnection service from its SSR procedures and insert them into Attachment X “merely moves this provision from one Tariff section to another without providing the requisite additional procedures.”

— Amanda Durish Cook

Federal Briefs

judgejohnprestonbaily(gov)
Baily

A federal judge rejected EPA’s effort to block a former official from testifying on behalf of a coal company that is suing the agency. The agency argued that Jeff Holmstead, a former EPA air pollution expert who left the agency in 2005, would have a conflict of interest because of his former position.

“That dog won’t hunt,” Judge John Preston Baily said of EPA’s argument. He also dismissed as “ridiculous” EPA’s claim that Holmstead was unqualified to testify as an expert witness.

Holmstead, who now works for law firm Bracewell, is an expert witness for Murray Energy. The company has sued EPA, alleging it has not accounted for or studied coal industry job losses resulting from its air pollution regulations, as required under the Clean Air Act.

More: The Hill

Senate to Consider Coal Cleanup Bill

senmariacantwell(wiki)
Cantwell

Four senators introduced a bill that would require coal companies to prove they have the resources to clean up mining areas after they close. Coal companies have been able to simply declare they can afford cleanup costs, without any financial assurance, a process called “self-bonding.”

The recent spate of coal company bankruptcies has called into question the ability of distressed coal producers to handle the cleanup costs.

“We need to make sure the taxpayer isn’t on the hook for cleanup work by bankrupt coal companies anymore,” Sen. Maria Cantwell (D-Wash.) said in a statement. “Self-bonding clearly isn’t working, and we need to stop this dicey practice from continuing.”

More: The Hill

Green Groups ask FERC for PennEast Pipeline Hearing

penneastpipeline(penneast)A group of environmental organizations is asking FERC to hold an evidentiary hearing on the need for the PennEast pipeline that would deliver natural gas from Pennsylvania mostly to New Jersey utilities.

“FERC must have substantial evidence of significant public benefit to approve PennEast’s application, but the company’s existing record fails to meet that test,” said a senior attorney with the Eastern Environmental Law Center. The center charges in a complaint that PennEast used the fact that six owners of the pipeline have contracted for about 75% of the proposed pipeline’s capacity as evidence of public need.

The New Jersey Sierra Club, however, didn’t join in the suit, saying the tactic would be unsuccessful. “What we’re more concerned about is that FERC and PennEast fix any defects they have in their applications and filings,” said Jeff Tittel, Sierra Club director.

More: Mercer Me

DOE Issues $82 Million in Nuclear Research Grants

departmentofenergy(gov)The Department of Energy has identified 93 projects in 28 states that will receive $82 million in grants to advance nuclear energy research.

“Nuclear power is our nation’s largest source of low-carbon electricity and is a vital component in our efforts to both provide affordable and reliable electricity and to combat climate change,” Energy Secretary Ernest Moniz said. “These awards will help scientists and engineers as they continue to innovate with advanced nuclear technologies.”

More: Department of Energy

NRC Names New Director of Office of Investigation

kimberlyhowell(gov)The Nuclear Regulatory Commission named Kimberly A. Howell as director of its Office of Investigation.

Howell, who has 20 years of federal law enforcement experience, was deputy assistant inspector general for investigations in the Office of Personnel Management. Before that, she held investigative positions with the Food and Drug Administration, the Secret Service and the Postal Service.

NRC’s investigation office creates new policies, procedures and standards for investigating licensees, contractors, vendors and other third-party organizations.

More: DailyEnergyInsider

EPA Moves Ahead with CPP Incentives Despite Stay

epajanetmccabe(gov)
McCabe

Despite a stay issued by the U.S. Supreme Court, EPA said it would go forward with a plan that issues incentives for states that comply with implementation of the Clean Power Plan.

“Taking these steps will help cut carbon pollution by encouraging investment in renewable energy and energy efficiency,” EPA’s Janet McCabe said. The Clean Energy Incentive Program gives states compliance credits for pushing forward renewable and efficiency projects.

The Supreme Court suspended enforcement of the Clean Power Plan until an appeal by states could be settled. “EPA is attempting to downplay the significance of the stay and argue against clear legal precedence as a last-ditch effort to scare states into spending scarce resources complying with a rule that could very well be overturned,” said Sen. James Inhofe (R-Okla.), chairman of the Environment and Public Works Committee.

More: The Hill

EIA Report: CPP Will Push Development of Renewables

energyinfoadmin(gov)An Energy Information Administration report concludes that EPA’s Clean Power Plan would accelerate the development of renewable energy at an annual rate of nearly 5%.

“California sees strong growth in renewable generation by 2030 as a result of the state renewable targets,” the EIA said. “Similarly, the Northwest region is expected to increase renewables generation as well. The Northeast shows an increase in both natural gas and renewables generation by 2030, and a small decline in nuclear generation due to planned retirements.”

EIA’s estimates were based upon the assumption the plan would be implemented. The plan is currently on hold as a result of a Supreme Court stay.

More: Morning Consult

Entergy’s Indian Point Unit 2 Back Online After Repairs

indianpoint(nrc)Entergy’s Indian Point Unit 2 nuclear plant went back into service late Thursday after a refueling outage, inspection and repairs. The repairs included replacement of 278 bolts and plates that were discovered damaged during an inspection.

A group of environmental organizations filed an unsuccessful emergency petition with the D.C. Circuit Court of Appeals to prevent Entergy from bringing the plant back online. Friends of the Earth and other groups said Entergy hasn’t provided a root cause analysis of the bolt degradation issue.

The Nuclear Regulatory Commission said there are no safety concerns. Entergy will conduct a separate bolt inspection at Unit 3 early next year.

More: Entergy; Friends of the Earth

Court Upholds Blocking Minn. Clean Energy Law

A federal appeals court upheld a ruling that Minnesota’s 2007 clean energy law illegally regulated out-of-state utilities by requiring state power producers who import electricity to reduce greenhouse gas emissions elsewhere.

The ruling by the 8th U.S. Circuit Court of Appeals was a victory for North Dakota and its utility and coal interests, which argued that the Minnesota law unconstitutionally hampered their ability to sell electricity from coal-fired power plants and to build new coal generators. The law, known as the Next Generation Energy Act, restricted electricity imports from power plants that increase greenhouse gases, unless they reduce those emissions.

The court’s decision does not affect the law’s requirement that Minnesota utilities get 25 to 30% of their electricity from renewable sources such as wind and solar.

More: Star Tribune

MISO Planning Subcommittee Briefs

MISO released a work plan last week detailing how it and PJM will use the next six months to improve coordination of generation retirements.

The RTOs’ cooperation on generator retirement studies was one of six directives mandated by MISO, PJM Working to Comply with NIPSCO Order.)

At last week’s Planning Subcommittee meeting, MISO said it and PJM will develop a proposal on retirement studies coordination by July.

MISO said it would work on the issue in meetings of the subcommittee, Planning Advisory Committee, and the RTOs’ Interregional Planning Stakeholder Advisory Committee and Joint and Common Market.

Neil Shah, MISO adviser of seams administration, said the RTOs would be starting from scratch. “The joint operating agreement doesn’t have any retirement coordination language,” he said.

miso planning subcommitteeThe RTOs differ on retirement rules. MISO requires 26 weeks’ notice prior to retirement, giving it time for a 75-day reliability assessment; PJM requires a 90-day notice and only 30 days of reliability assessment. Further, MISO keeps retirement information confidential unless a reliability concern is identified. PJM has no such confidentially rules and makes retirement information publicly available.

Shah said MISO would submit its work plan to FERC with an informational status filing that is due June 20. Additional status filings are due Aug. 19 and Oct. 18.

He also said MISO plans to share draft JOA language with stakeholders at the RTOs’ Nov. 15 joint and common issues meeting in time to file proposed JOA revisions with FERC by Dec 15.

Pseudo-Ties to Require System Impact Studies; Would be Barred from Sink Switching

MISO wants to conduct system impact studies on all pseudo-tied units with transmission service requests and forbid them from switching sinks until the requests expire.

The RTO is proposing a system impact study be required for all pseudo-tie transmission service requests and that firm point-to-point transmission service be required for the life of the pseudo-tie.

MISO has also proposed that pseudo-tied exports be sourced from a designated generating facility in its commercial model and be modeled in the external balancing authority. Pseudo-tied imports must be sourced from the local balancing authority where the generating unit is physically located and must sink into the MISO local balancing authority where the unit is being pseudo-tied.

“Participants are changing pseudo-ties to another sink after they have a transmission service request,” MISO senior transmission planning engineer Ankit Pahwa said. “It’s a shortcoming in the existing process … and a gray area that has not been covered yet.”

Pahwa said the proposed changes have been coordinated with PJM. He added that participants with existing pseudo-tied transmission service requests would be grandfathered from an impact restudy.

Currently, transmission service requests are evaluated based on an OASIS available flowgate capability evaluation, with only long-term requests — 18 months or longer — requiring a system impact study. Neither long-term nor short-term requests require a source/sink analysis, Pahwa said.

“From MISO’s perspective, we want to be 100% sure that we capture the transmission service impacts if a pseudo-tie moves to a different [local balancing authority],” Pahwa said.

“I think what we’re wrestling here is, does there need to be different treatment for pseudo-ties … much like there are different evaluations for network resource interconnection service for reliability purposes? At the minimum, you need to be sure you have the appropriate type of analysis,” MISO’s Jeff Webb said.

Webb said more conversations with other RTOs were needed before a final proposal. Stakeholders have until July 15 to comment on MISO’s proposal.

MISO Delves into MTEP 16 Studies

MISO is in the midst of developing model scopes for the 2016 Transmission Expansion Plan (MTEP 16), said Dave Ditner of the RTO’s system modeling department. The RTO’s modeling will include a 2017 summer peak with wind contributions of 15.6% and 2021 modeling of summer peak, summer shoulder and light load scenarios with wind contributions ranging from 15.6 to 90%.

MTEP16 Transfer Studies (MISO) MISO planning subcommittee

William Kenney, an expansion planning engineer for MISO’s Southern Region, also presented the finalized MTEP 16 voltage study scope. The study will use nine 2021 power flow models, including summer, winter and a shoulder with wind at 40%. MISO will release the final MTEP 16 voltage stability study in October.

Additionally, seven transfers will be studied in model year 2021 under the MTEP 16 transfer analysis scope:

  • MISO North to SPP;
  • Two different paths from Manitoba Hydro to MISO North;
  • PJM in Northern Illinois to PJM Ohio;
  • Missouri and Illinois to PJM Ohio;
  • SPP to Southern Co.’s territory; and
  • MISO South to SPP.

MISO will finalize the transfer analysis in mid-August.

Storage May Be Removed from Non-Transmission Alternatives

MISO presented stakeholders with draft language on Business Practices Manual 020, continuing a nearly yearlong discussion on non-transmission alternatives.

The RTO is suggesting separating energy storage devices that could solve a transmission issue from BPM language on non-transmission alternatives. MISO is also recommending discussion on whether storage can serve as a non-traditional transmission alternative move to the Planning Advisory Committee, MISO’s Matt Tackett said.

In April, MISO proposed classifying storage as a non-traditional transmission alternative. (See “Energy Storage Prompts 2nd Transmission Alternative Category,” MISO Planning Subcommittee Briefs.)

Indianapolis Power & Light’s Lin Franks said storage provides frequency control and voltage control much like transmission.

MISO will present a second draft of the BPM language at the August Planning Subcommittee meeting.

— Amanda Durish Cook