September 27, 2024

CAISO Solar Eclipse Prep Relies on Conventional Mix

By Robert Mullin

CAISO will lean heavily on increased output from conventional generators — and a backstop of regulation reserves — to fill the void left by reduced energy production from California solar resources during next month’s solar eclipse.

The grid operator estimates that about 4,194 MW of utility-scale solar will fall off the system from the time the moon begins to pass in front of the sun (9 a.m.) to the moment of peak obscuration (10:22 a.m.) during the Aug. 21 event.

caiso solar eclipse
Graph shows a comparison between CAISO’s Aug. 21 eclipse load forecast compared with that for full-sun conditions. | CAISO

At the peak, grid-connected solar generation will come up about 5,600 MW short of what would be expected under full-sun conditions. Net load will surge to about 6,000 MW above normal because of diminished output from rooftop installations.

But the grid operator has been preparing its response since last year. (See CAISO Planners Looking Ahead to Summer 2017 Solar Eclipse and With Solar Eclipse Looming, CAISO Weighs its Options.) After a winter of ample precipitation, “large and fast-moving” hydroelectric resources are being positioned for rapid response during both the loss and return of solar, according to Deane Lyon, a CAISO real-time operations shift manager.

Planners are also banking on gas-fired generators to help cover the gap.

“We’re actually working with Pacific Gas and Electric and [Southern California Gas] and coordinating with their gas control centers because, besides the hydro, the gas-fired thermal is going to have to make up for a lot of the loss of solar generation,” Lyon said Tuesday during a bimonthly Market Performance and Planning Forum.

The ISO will also procure about 900 to 1,200 MW of regulation up reserves for the three-hour period affected by the eclipse — compared with a typical procurement of 300 to 400 MW.

“That’ll help us manage as the solar goes away,” Lyon said.

Lyon noted that CAISO has been consulting with Western Energy Imbalance Market (EIM) participants to develop a “consistent policy” regarding transfer service requests (ETSRs) — or dynamic transfers across balancing areas — during the eclipse so that the ISO can take advantage of imports to the greatest extent possible.

“We got commitments from the operations folks at the EIM entities that they’re willing to keep the ETSRs wide open and fully operational for the balance of the eclipse,” Lyon said, acknowledging that the ISO does not expect a “huge” uptick in transfers given that Arizona Public Service and NV Energy will also be losing solar off their systems at about the same time.

On the flip side, the eclipse is not expected to actually undercut imports.

“APS has solar, but not PacifiCorp,” Lyon said. “We don’t expect it will have that big of an effect.”

Paula Lipka, of PG&E’s short-term electricity supply team, asked if the ISO intends to increase its procurement of flexible ramping and spinning reserves — as well as regulation.

“An increase in flex ramp procurement is being considered. As far as spinning and non-spinning reserves, we will have adequate amounts of that,” Lyon responded.

Regulation reserves are the ISO’s key concern.

“We’re trying to maintain our system balance for the duration of the sun going away and returning, which is going to be a pretty big challenge,” Lyon said.

SPP Seeks Experts for Competitive Tx Panel

SPP is accepting applications from industry experts to serve on an independent panel reviewing the RTO’s 2018 competitive transmission construction proposals.

The panel will review, rank and score proposals for competitive projects under FERC Order 1000. The previous two panels recommended one such project — a 22.6-mile, 115-kV line from Walkemeyer to North Liberal in southwest Kansas. However, the project was withdrawn because of decreased load projections. (See SPP Cancels First Competitive Tx Project, Citing Falling Demand Projections.)

spp competitive transmission
| Westar

Interested candidates must have expertise in at least one of the following transmission-related areas:

  • Engineering design;
  • Project management and construction;
  • Operations;
  • Rate design and analysis; or
  • Finance.

SPP will accept applications through Sept. 1 and choose panelists later this year based on recommendations by the RTO’s Oversight Committee, which must be approved by the Board of Directors. Selected panelists will be considered contractors and will be compensated through a monthly retainer and hourly rate.

Panelist applications, instructions and more information can be found on SPP’s website or by contacting Ben Bright, the RTO’s regulatory processes manager.

— Tom Kleckner

MISO Resource Adequacy Subcommittee Briefs: July 12, 2017

MISO has introduced a three-step checklist that owners of behind-the-meter (BTM) generation can use to prove deliverability for the Planning Resource Auction, but some stakeholders are calling foul on the differing auction requirements.

The three-pronged approach will involve different sign-offs from affected load-serving entities, transmission owners and MISO. The LSE will determine whether the BTM customer can participate in the wholesale or retail market, while the TO will ascertain study requirements for access to the transmission system when the BTM generator interconnects to a non-transferred facility. The RTO will determine the resource’s deliverability or transmission service procurement in order to use the transmission system.

btm generation MISO Resource Adequacy Subcommittee Briefs
| MISO

“This is meant to provide some guidance on the more intricate relationship between LSEs and TOs,” MISO Manager of Resource Adequacy John Harmon said during a July 12 Resource Adequacy Subcommittee meeting. “MISO is not looking to gain new authority in this endeavor; we’re trying to stay within the bounds of our Tariff.”

Since the beginning of the year, MISO staff have been grappling with deliverability rules that would allow BTM generation in excess of a utility’s planning reserve margin requirement — but without existing transmission service — to enter the annual capacity auction. The RTO last month proposed requiring that a BTM resource submit to an optional engineering study to identify a deliverable volume of capacity eligible to be bid into a single auction. However, the study would have only temporary value. The resource would then be required to enter the same volume into the interconnection queue study process before offering capacity into any subsequent auctions. (See MISO Proposes Deliverability Rules for Behind-the-Meter Capacity.)

Harmon said MISO is proposing to adopt the optional study avenue for two planning years until June 1, 2019. After that, resource owners will have to enter the interconnection queue.

Deliverability amounts discovered in the optional study will have a “limited applicability” and will not be used to determine deliverability in the interconnection queue process, Harmon said.

Indianapolis Power and Light’s Lin Franks asked why BTM generation should essentially be treated as “free riders” on the grid, and not supported by utility aggregators.

“I don’t know of any place where behind-the-meter generation [has] paid for transmission service. They’ve paid nothing whatsoever for access to the Bulk Electric System,” Franks said. “There are some holes.”

Harmon said BTM will only have access on an as-available basis, and that the proposal is an “interim solution” to ushering BTM generation into a more formal interconnection process.

Dynegy’s Mark Volpe asked if MISO was proposing a go-around to the rules that every other capacity resource has to abide by.

“You’ve got a gigantic comparability issue here,” Volpe said.

MISO Resource Adequacy Subcommittee Briefs BTM generation
| MISO

Harmon pointed out that before this year, excess BTM generation was delivered undetected. “We think there’s good cause for a transition period,” Harmon said. He also added that the proposal might not be “100%” yet, but that MISO and stakeholders are striving toward the same goal.

He asked for additional stakeholder feedback on the deliverability proposal by July 26.

PRA Qualification Deferral to Become a Reality

MISO will file Tariff changes this fall to give certain capacity resources the option for additional time to qualify for the PRA.

The deferral will also be spelled out in the Business Practices Manuals and will allow certain resources to postpone completion of generator verification tests or installed capacity value calculations until after the auction. Capacity resource owners that intend to defer must inform the RTO before Feb. 15 and complete a generator verification test no later than May 31 in order to participate in the upcoming planning year.

MISO uses the verification test to determine the total capacity that a planning resource can reliably provide based on performance and availability data for summer peak conditions.

The draft BPM language states that the deferral is for untested new planning resources, existing resources “returning to operation from a catastrophic outage or suspension,” resources in the midst of increasing capability, suspended resources and resources “awaiting other miscellaneous resource approvals to achieve commercial operation.”

Analyst Scott Thompson said deferrals could also be used by intermittent capacity resources that have yet to come online at the time of the auction or generators that are completing environmental upgrades that prevent operation.

— Amanda Durish Cook

4 LMRs Face Penalties after MISO Max Gen Emergency

By Amanda Durish Cook

Most load-modifying resources called up for the first time in a decade during MISO’s April 4 maximum generation event failed to respond properly to scheduling instructions, officials said last week.

MISO load-modifying resources
Harmon | © RTO Insider

MISO Manager of Resource Adequacy John Harmon said 19 LMRs — demand resources and behind-the-meter generation that provide capacity — responded to meet a maximum scheduling instruction of 715 MW during the emergency in MISO South. Four LMRs failed respond at all and will face penalties under Module E of the RTO’s Tariff.

Harmon said the underperformance by some LMRs was offset by the larger-than-expected load reductions by others. The RTO was short about 25 MW of scheduling instructions in the last hour of the emergency declaration.

He stressed the importance of LMR owners providing accurate load curtailment capability to MISO every day. “It’s important that LMRs update their availability daily in the MISO communication system. Our operators rely on these each day and … are banking on the numbers when the need could arise to shed firm load,” Harmon said at a July 13 Market Subcommittee meeting.

LMRs are only required to be available for emergencies during the summer peak season and do not have to be available during non-summer months. However, the plants must notify MISO when they are unavailable through the RTO’s communication system.

In May, the RTO promised to conduct a performance evaluation of the LMRs during the event. (See “Several Factors in Spring MISO South Maximum Generation Event,” MISO Market Subcommittee Briefs.)

MISO load-modifying resources
April 4, 2017 Max Gen Event Conditions | MISO

MISO has calculated a total penalty of about $2,000 for the four LMRs that failed to respond. The revenue from the penalties will be allocated to all market participants with load in the Entergy Arkansas local balancing authority, and on a market load ratio share basis to the Entergy New Orleans, Louisiana, Texas and Mississippi LBAs.

The RTO will assess and begin to distribute penalties this week. The generators could avoid punishment if they can identify force majeure reasons that prevented them from responding.

Harmon said MISO will review its approach to training and operations drills to improve LMR performance. It also will review its current process and Tariff to make sure LMRs are “incentivized to update availability each operating day,” he said.

“We saw a lower rate of LMRs being able to meet the load reduction that they said they could meet. That suggests to us that market participants can tighten up the precision of the information that they provide to MISO on a daily basis,” Harmon said.

Executive Director of Market Design Jeff Bladen said there might be a disconnect between what market participants can provide in load curtailment and MISO’s scheduling instructions.

“The issue is when someone tells us that they can drop from 100 MW to 10 MW, and they’re operating at 70 MW and drop to 10 MW, that’s not a 90-MW drop; that’s a 60-MW drop. Whether there’s a penalty or not, we want to operate reliably. It’s not a question of right or wrong, it’s a question of can we operate reliably,” Bladen said.

The April 4 event was driven by unseasonably high temperatures and an unusually high amount of transmission and generation outages in MISO South. It prompted the Independent Market Monitor to call for greater MISO authority in approving maintenance outages. (See MISO South Outages Worry RTO, Monitor.)

PJM OC Briefs: July 11, 2017

VALLEY FORGE, Pa. — PJM last week presented Operating Committee members with a proposed pro forma agreement for dynamic schedules, saying it would eliminate potential confusion and improve reliability.

Dynamic schedules are power flows into the RTO from a generator that is controlled by and located in a different grid operator’s territory. Unlike pseudo-tied units, the flows are not modeled in PJM’s systems as internal supply.

pjm dynamic schedules
D’Antonio | © RTO Insider

Because PJM lacks a standard agreement for dynamic schedules, individual agreements may contain variations in language that can result in incorrect operating procedures, the RTO said.

Under PJM’s proposal, the native balancing authority would only need to acknowledge awareness of the agreement because it remains operationally responsible for the resource. Unlike pseudo-ties, dynamic schedules require tagging and are subject to curtailment under NERC’s transmission loading relief procedures, PJM’s Phil D’Antonio said.

D’Antonio said PJM hadn’t yet decided whether they would seek to make the agreement retroactively enforceable for existing schedules. The agreement will be brought to a vote at next month’s OC meeting.

Hugee | © RTO Insider

PJM’s Jacqui Hugee gave the OC an update on additional Joint Operating Agreement revisions MISO has requested relating to the pro forma pseudo-tie agreement. “For the most part, the changes are to clarify the language that is there,” she said. (See Late Agreement with MISO Forces Another Delay on Pseudo-Ties.)

Stakeholders voiced concerns about the language, but Hugee explained that PJM does not need, nor will it seek, stakeholder endorsement for the changes.

SCED Changes Implemented

PJM on Monday transitioned from a 15-minute to a 10-minute “look ahead” on its security-constrained economic dispatch (SCED) engine. The changes went into effect at 9 a.m.

Ciabattoni | © RTO Insider

PJM’s Joe Ciabattoni said the RTO will review the system’s performance after a week to ensure there are no reliability issues and evaluate whether to retain the changes. Ciabattoni said PJM does not need stakeholder approval to make the changes.

“We’re trying to better align real-time reserve levels with reserves calculated and dispatched by SCED,” he said. “Historically, we started with a 22-minute look ahead and have moved it over time to 15 minutes.”

Resilience Planning Moves Forward

PJM’s Jonathon Monken reviewed the RTO’s ongoing development of system resilience, noting that communication has expanded with related industries such as natural gas distributors. (See “Bryson Leads on Next Steps for Fuel Resiliency,” PJM OC Briefs.)

“I would expect that this will drive a lot of exercises and drills, recognizing that when we identify a vulnerability, we would much prefer to test it in an exercise environment than experience it in real life,” said Monken, senior director of systems resilience and strategic coordination.

He said that PJM is developing both internal and external roadmaps for enhancing resilience to severe weather, physical or cyber attacks or disruptions in fuel supplies. He also reviewed PJM’s Resilience Steering Committee, which includes himself and 14 other PJM staffers with responsibilities for various aspects of the plan.

John Farber of the Delaware Public Service Commission questioned using resilience as a driver for approving projects in the Regional Transmission Expansion Plan. While it was not listed on the current version of the external roadmap he presented, Monken confirmed that it is still a focus.

Farber warned that evaluation of resilience in RTEP projects wouldn’t be “as straightforward as described” and said completing quantifiable metrics by the end of 2018 is an aggressive timeline. “I would just note that the last time that PJM addressed drivers in the RTEP process … that took two and a half years. And those were, in my view anyway, difficult years,” he said.

“We certainly recognize the fact that we’re certainly not going to go faster than what the stakeholders would like it to go,” Monken said.

Ramp Rate Changes

PJM’s Cheryl Mae Velasco highlighted enhancements to its Markets Gateway online tool that will allow generators to adjust their regulation offers throughout the day instead of just once daily.

“The [web-coding] vendor had a chance to put them in,” Velasco said. “They’ve been on the backlog for quite a while.”

The announcement was met with appreciation, but also a request.

“These are items that could provide optionality in how we operate units, so to hear about it in the Operating Committee a week before [implementation] is, for me at least, problematic,” American Electric Power’s Brock Ondayko said. He asked that similar changes be brought to stakeholders’ attention “preferably” two or three months in advance.

“Once we found out [that the vendor had made the updates], we sent the communications out as soon as possible,” Velasco responded.

PJM’s Ken Seiler acknowledged Ondayko’s concern and said he would work with the RTO’s Tech Change Forum to provide earlier notice in the future.

Ciabattoni said that generators making changes to their ramp rates will not require corresponding price points in their cost-based offers.

Solar Eclipse Impacts

pjm dynamic schedules
Mulhern | © RTO Insider

PJM estimates a loss of up to 2,500 MW in solar output during the solar eclipse that will occur on Aug. 21. The event is expected to last about an hour.

While grid-connected and behind-the-meter systems will be impacted the same, the difference in deployed amounts means that grid-connected output is expected to drop about 500 MW, while BTM resources could drop about 2,000 MW. PJM expects it will need to increase non-solar generation by about 1,000 MW if it’s an overcast day and up to 2,500 MW if it’s sunny. Coordination will be important during the ramp up and ramp down periods.

PJM’s Joe Mulhern said the eclipse is expected in the middle of the afternoon when the sun is high and solar generation is near its peak output. If it’s a hot day, load will no doubt be near its peak as well, he said. However, a NERC analysis showed no reliability impacts are expected for the Bulk Power System.

pjm dynamic schedule
Boyle | © RTO Insider

Primary FR Task Force Begins July 25

PJM’s Glen Boyle announced that the Primary Frequency Response Senior Task Force will have its first meeting at 9 a.m. July 25, with monthly meetings to follow for at least six months. (See “PJM Defends Interest in Paying for Frequency Response,” PJM Markets and Reliability Committee Briefs.)

– Rory D. Sweeney

PJM MIC Briefs: July 12, 2017

VALLEY FORGE, Pa. — PJM’s Lisa Morelli presented the Market Implementation Committee last week with revisions to the RTO’s proposal for handling intraday hourly offers in the energy market, delaying a scheduled vote on the plan.

Morelli | © RTO Insider

The changes made to Manual 11: Energy & Ancillary Services since the first read on the proposal included a clarification that PJM’s real-time security constrained economic dispatch (SCED) uses data that are effective for the look-ahead solution interval rather than the case execution time. In response to feedback from the Independent Market Monitor, it also clarifies that a generator’s intraday opt-out election must be consistent with its fuel-cost policy.

IMM staffers Siva Josyula and Joel Romero Luna also outlined the Monitor’s concerns with PJM’s proposal. (See “IMM’s Proposed Fuel-Cost Policy Changes Denied,” PJM Markets and Reliability and Members Committees Briefs.)

Josyula | © RTO Insider

“Resources should not be able to circumvent [market power] mitigation just by changing the relative levels of price versus cost,” Josyula said.

Luna focused on how generators can elect to opt out of intraday offers. PJM’s rules require that if generators change their price-based offer, they must also change their cost-based offer, he explained. “It’ll be easier for anyone who has a fuel-cost policy to say, ‘If I don’t have it in there, my default is to opt out,’” he said. “If no one changes their fuel-cost policies to incorporate hourly offers, it’s not clear how they can be compliant with the rule that has been presented because [hourly offers] can change your cost-based offer.”

It’s unclear whether the Monitor’s differences will result in separate proposals.

“It might be separate. We’re not completely there yet to say … they are, in fact, two different things. That might be where we end up in another round of conversations,” said PJM’s Chantal Hendrzak, who chairs the MIC.

Morelli also announced that all generators, no matter if they plan to update schedules hourly or not, will need to update their schedule IDs to PJM’s new list by Nov. 1. The RTO will be posting a step-by-step guide in its Markets Gateway online tool. With the implementation of intraday offers, PJM will only accept cost-based schedules 1-9, eliminating 70 others. The number of price-based schedules is being reduced from 19 to two.

PJM Indifferent on Black Start Fuel Compensation

Before presenting proposals from Calpine and the Monitor on calculating fuel-storage compensation for black start units, PJM’s Tom Hauske made it clear the RTO is agnostic to the voting results. He was repeatedly asked for PJM’s position, and he repeatedly declined to take one. (See “Started from the Bottom, Now We’re at the MTSL,” PJM Market Implementation Committee Briefs.)

“What we’ve taken as a position is that we can live with any of the three,” he said, including the status quo among the options.

The Monitor’s proposal would calculate the unit’s compensation for fuel storage — known as minimum tank suction level (MTSL) — based on the ratio of the fuel tank’s total volume to the amount of fuel needed to fulfill the black start requirements of 16 hours of continuous operation. The proposal from Calpine’s David “Scarp” Scarpignato would compensate units based on the average annual fuel volume in the tank.

Bowring | © RTO Insider

Scarp and Monitor Joe Bowring sparred for a while on the merits of Scarp’s proposal. Bowring asked why “black start should pay an even bigger piece based on whatever random amount of oil is in the tank.” PJM currently pays about $500,000 per year in compensation for black start fuel storage based on current rules that pay for the entire tank. So either proposal would reduce the costs, the sponsors say.

The conversation between Scarp and Bowring eventually devolved into a fast-food metaphor focused on how much frying oil a restaurant would need to switch menu options. At the end, Scarp asked for clarification on whether his proposal would be set for a vote as an alternative to the Monitor’s proposal. When that was confirmed, he explained that he only meant for his proposal to spur discussion and asked that it be removed.

The vote at next month’s meeting will be on the Monitor’s proposal versus the status quo. Greg Poulos, executive director of the Consumer Advocates of the PJM States, announced his membership is leaning toward the Monitor’s proposal.

Energy Efficiency Kicked to Demand Response Subcommittee

PJM staff canceled plans to begin discussions in the MIC regarding rules for energy-efficiency products entering into the capacity market after stakeholders said they could resolve the issues more quickly through the Demand Response Subcommittee first. (See “EE Problem Statement Narrowly Approved,” PJM Market Implementation Committee Briefs.)

CPower’s Bruce Campbell pushed back on the change of venue, saying it will be difficult for the subcommittee to cover DR, the energy efficiency rules and how to address the impact of state policy initiatives on the markets.

PJM’s Pete Langbein warned that the four- to six-month timeline for results indicated in the energy-efficiency issue charge is “very aggressive.”

IMM Presents Problem Statements on Transmission

Bowring presented two problem statements and issue charges related to transmission concerns on first reading. The first problem statement and issue charge focuses on transmission penalty factors, for which he said PJM has no rules.

In its dispatch model, PJM allows transmission constraints to be violated under some conditions. The violated constraints have defined penalty factors that affect LMPs to reflect the local scarcity. Bowring says the penalty factor for a violated constraint should equal the shadow price — the incremental reduction in congestion cost achieved by relieving a constraint by 1 MW. PJM, however, uses “constraint relaxation logic” to affect the shadow prices, typically causing the shadow price to be slightly below the penalty factor, Bowring says.

Other grid operators, such as MISO, have explicit rules on the topic, he said.

In a presentation on the issue at the Members Committee webinar last September, Bowring recommended that PJM explicitly state its policy on the use of transmission penalty factors: the level of the penalty factors; the line ratings to trigger their use; the allowed duration of a violation; and when the penalty factors will be used to set the shadow price.

In asking you to approve this problem statement, I’m not asking you to agree with my characterization,” he told the MIC on Wednesday. “There are no rules. It should be written down. … I don’t know how long it’s been occurring at PJM — probably since the beginning.”

Morelli said PJM is in favor of the problem statement. “In addition to adding some consistency to how some of this works, it’s also taking a look at constraint reorganization where, essentially, we don’t allow the penalty factors to set price,” she said.

The second problem statement and issue charge focuses on pricing point alignment for cross-border transactions. The current procedure allows for “scheduling energy inconsistent with power flows” that “creates harmful market inefficiencies,” according to the problem statement.

“Our underlying principle is that pricing should be consistent with physical power flows — a radical concept, I know, but it’s not currently being implemented,” Bowring said.

— Rory D. Sweeney

PJM: No Change on MOPR Yet; Remand May Have Little Impact

By Rory D. Sweeney

VALLEY FORGE, Pa. — PJM said last week that a court ruling remanding a FERC order on the RTO’s minimum offer price rule won’t have any impact until the commission addresses the decision. And it may have little practical impact even after that, PJM’s Jen Tribulski told the Market Implementation Committee on Wednesday.

The July 7 ruling from the D.C. Circuit Court of Appeals said the commission overstepped its authority when it denied a 2012 proposal from PJM to revise its MOPR provisions but then spelled out to the RTO what it would approve. PJM’s proposal — a compromise between generators and load-serving entities — would have replaced the unit-specific MOPR exemption with two new ones and extended the mitigation period from one to three years before a unit could bid below the price floor.

Compromise Eliminated

FERC said it would accept the additional two exemptions if the unit-specific review were retained and the mitigation period remained unchanged. PJM agreed to FERC’s changes even though it eliminated the deal PJM stakeholders had made to secure stakeholder endorsement of the proposal. (See PJM MOPR Order Reversed; FERC Overstepped, Court Says.)

FERC’s ruling was vacated and remanded back to the commission, which must now write a new order for PJM. That can’t happen until the commission restores its quorum. (See related story, Trump Names Energy Lawyer McIntyre as FERC Chair.)

compr
Tribulski | © RTO Insider

“The court really only ruled on the legal issue of whether FERC exceeded its authority under Section 205,” Tribulski said. “Until those rules are changed on remand, that’s our filed rate.” She acknowledged suggestions from stakeholders to revert to the previous rate or to PJM’s original proposal, but she said neither of those are appropriate because they are not what is currently approved by FERC and the court didn’t entirely vacate that approval.

PJM also isn’t planning to revise any auction results unless FERC orders a rules change. “We will wait to see what FERC does,” Tribulski said.

Gabel Associates’ Mike Borgatti asked how this might impact generators’ decision-making for filing exemptions, given that the exemptions for the 2018 Base Residual Auction must be requested by the end of this year. It will be at least until Aug. 28 that the ruling is even remanded to FERC, Tribulski said, noting a 45-day appeals period and another seven days following that for the order to become official. That also assumes the commission will have a quorum by then and be caught up on its existing backlog of filings.

‘Less than Meets the Eye’

She said there also might be “less than meets the eye here” because there haven’t been any unit-specific exemptions approved while the vacated rules have been in effect. Unit-specific exemptions are the part of PJM’s original MOPR proposal that FERC denied and recommended should be retained. “There may not be that big of an actual, practical impact,” she said.

Barker | © RTO Insider

Exelon’s Jason Barker said that as PJM is considering what parts of the ruling haven’t been vacated, the RTO needs to be aware that stakeholders still wouldn’t have had an opportunity to comment on them, which was a key part of the appeal.

“When FERC ‘imposes an entirely new rate scheme’ in response to a utility’s proposal, the utility’s customers do not have adequate notice of the proposed rate changes or an adequate opportunity to comment on the proposed changes,” the court said. “That was the case here.”

SPP Markets and Operations Policy Committee Briefs: July 11-12, 2017

DENVER — SPP’s Z2 Task Force will likely soon be a relic of the past, but the issues with financial credits and obligations for sponsored transmission upgrades that spurred the creation of the group aren’t going away.

The Markets and Operations Policy Committee last week endorsed the task force’s request to conclude its work. Minutes later, SPP staff told the committee the RTO would have to resettle nine years of historical Z2 credits and obligations because of billing disputes, “minor” software defects and problems in calculating the present value of creditable balances.

z2 task force spp mopc
SPP’s Markets and Policy Operations committee underway | © RTO Insider

SPP last fall identified about $200 million in revenue credits to be collected for transmission upgrades under its Tariff’s Attachment Z2, which details how to reimburse sponsors of network upgrades. The bills covered eight years of credits and obligations for 2008-2016, when staff failed to apply credits, complicating the task of trying to accurately compensate project sponsors and claw back money from members with debts for the upgrades. (See Preliminary Z2 Bills Released; Task Force Develops Options for Waiver Requests.)

SPP’s Charles Locke said the resettlement results will be similar to last year’s processing and stressed they will not produce duplicate or additional charges.

“What you pay or owe is only the difference between the original settlement and the resettlement,” he said.

However, Locke could provide few details beyond that. “Generally, the amounts will be small. I’m reluctant to say how small,” he said.

That drew pushback from members, some of whom could recall early staff estimates of $50 million for creditable transmission upgrade projects, which eventually ballooned to nearly $850 million in assigned costs. (See SPP MOPC Recommends 5-Year Timetable for Resolving $849M Z2 Bill.)

“Is there a number by what you mean by small?” asked ITC Holdings’ Marguerite Wagner. “It’s hard for me to understand what that actually means.”

SPS’ Bill Grant | © RTO Insider

“SPP assured us for years the amounts for Z2 were small, until they actually did the billing,” said Southwest Public Service’s Bill Grant. “I don’t get a lot of comfort when you say the amounts will be small. I do understand the reason, but it still tends to create regulatory issues for your members when they go back [to their commissions] and say, ‘Whoops! The calculations weren’t correct, so we’ll have to adjust it either up or down.’ It’s starting to get really painful.”

SPP COO Carl Monroe suggested that members focus on the difference between last year’s invoices and this year’s.

“What’s more important is the deltas,” he said. “We won’t know the deltas until we know the details of the resettlement. We won’t know the details until we go through the actual resettlement.”

Locke said staff intends to provide preliminary resettlement results in September, so members “at least have some indication of the numbers.” Staff will in September begin reprocessing data from March 2008, adding the months through July 2017. It hopes to post updated invoices in October to keep up with a timeline approved last year.

While chairing the Strategic Planning Committee on July 13, Golden Spread Electric Cooperative’s Mike Wise asked Locke whether the resettlement would be SPP’s last.

“We’re certainly hoping so,” Locke responded. “The last resettlement of historic data.”

In accepting the Z2 Task Force’s recommendation to let its charter expire, the MOPC also approved two recommendations from the group, with nine “no” votes (out of a potential 95 votes) and two abstentions. The first eliminated credits for non-capacity upgrades, such as substation facilities, while the second disposed of credits for short-term transmission service of less than a year.

The task force also reviewed the use of incremental long-term congestion rights (ILTCRs) as a substitute for Z2 credits — a practice by other RTOs — but was unable to reach consensus. The group said “significant concern” was expressed over SPP’s existing congestion rights processes and the “perceived lack of hedging.”

“Existing customers may prefer the risk of waiting on cash recovery versus getting ILTCR’s, which may have limited value in the future,” according to the task force’s recommendation to the MOPC.

The task force was formed last year to find “a more rounded solution” to Z2 credits. (See Board Approves Z2 Timeline Extension, Creates Task Force for Further Study.)

SPP z2 task force mopc
AEP’s Richard Ross | © RTO Insider

“We feel like at this point in time, the task force has done what it can about whether or not there is something else we can do to reduce the burden of Z2 and replace it with something else,” the task force’s chair, Kansas City Power & Light’s Denise Buffington, told the MOPC. “After many, many, many meetings, we could not get to a decision on the underlying policy or whether to socialize those costs. Unfortunately, we are where we are.”

American Electric Power’s Richard Ross, who likes to hand out gold stars to his fellow stakeholders, said he was awarding Buffington a “Richard Ross Gold Star for Cat Herder of the Year.”

MOPC Suggests 1-MW Threshold for Network Load

It came down to a single vote, but the MOPC offered direction to the Regional Tariff Working Group on how to address “inconsistency and uncertainty” over which behind-the-meter generation qualifies as network load.

The committee directed the RTWG to use a 1-MW threshold for reporting network load and to develop a list of inclusions and exclusions. In a roll-call vote, the last member to record its vote pushed approval of the motion from 65% to 66.2% — just above the 66% necessary for passage.

For customers taking network service, SPP currently follows FERC policy that sets all load at discrete delivery points as network load, which effectively sets the threshold at 0 MW for load served by BTM resources.

“At least this gives some guidance to MOPC,” Monroe said, alluding to the difficulties the RTWG has had in tackling the issue.

z2 task force spp mopc
OG&E’s David Kays | © RTO Insider

“If so, then make every member of the MOPC charter members of the [RTWG’s] Billing Determinants Task Force, because that is what we spent two and a half years discussing,” said Oklahoma Gas & Electric’s David Kays, who chairs the RTWG. “If 10 members were in the room, we had 10 different exceptions. If 15 members were in the room, then we had 15 different exceptions.”

The RTWG, through the BDTF, has been working on the problem since 2014 and has haggled over two revision requests (RR158 and RR 232). The task force developed the first and defined network load to include load served by certain BTM generators at discrete delivery points, while excluding load served by other BTM generators where load is shed automatically. The second revision request was developed with input from the SPC and excluded load served by a BTM generator or group of generators totaling 1 MW or less.

Members were never able to reach consensus on the proposed Tariff language. The RTWG in June rejected RR158 and RR232.

“We spent significant time on RR232 trying to cover as many issues related to behind-the-meter generation as possible,” said BDTF Chair Heather Starnes, legal counsel for the Missouri Joint Municipal Electric Utility Commission. “Different people interpret the Tariff provisions related to network load … differently. Maybe it’s not so straightforward to some folks.”

The RTWG will bring back its list of exclusions and inclusions to the October governance meetings. Assuming clarity and approval of the network load list, Starnes said, the RTWG will then develop Tariff language once again subject to the stakeholder process.

“This is a need, an immediate need,” Wise said. “I think there may be some cross-subsidization going on because of the way the network load is actually reported. I want to make sure we have consistency across the entire footprint and where the whole load gets reported accurately, because we do have substantial costs paid by the network load. All these loads need to pay their fair share of those costs.”

Staff to Review AECI Joint Project After Cost Increase

David Kelley, SPP’s director of interregional relations, told members he would spend this week reviewing an alternative to a previously approved transmission project that recently saw a 50% cost increase.

The joint project with Associated Electric Cooperative Inc., originally estimated at $9.2 million, was endorsed by the MOPC and SPP Board of Directors in January and included in the RTO’s 2017 Integrated Transmission Planning 10-year assessment. It involves installing a new 345/161-kV transformer at AECI’s Morgan substation and an uprate of a related 161-kV line, both near Springfield, Mo.

“As luck would have it,” Kelley said, AECI notified him July 7 that it raised the project’s cost estimate to “just shy of $14 million.” Because the costs increased more than 20%, the parties can revisit the initial cost-sharing agreement.

“We had another alternative that wasn’t a seams project. It provided comparable benefits but, at the time, significantly more expenses,” Kelley said. “I’d like to spend the next few days making sure we’re still making the right decision.”

Kelley said if his revised analysis is not ready for the July 25 board meeting, he will present it during the October governance meetings.

The Morgan project would be regionally funded, as it solves congestion issues on SPP’s side of the seam, and is contingent on reaching an agreement for compensating AECI. SPP was to assume responsibility of $8.7 million of the original cost estimate. AECI will own the project and be responsible for its construction, operations and maintenance.

MWG to take Another Shot at MWP Manipulation

Members remanded back to the Market Working Group a previously rejected revision request (RR221) that addressed potential manipulation of make-whole payments (MWPs) related to mitigated energy offers and no-load offers for resources with a three-day minimum run time or greater.

RR221 would have added language that establishes a permissible percentage threshold above the mitigated offer at the time of the original commitment. Ross, the MWG’s chair, said that as structured, RR221 would force SPP to report to FERC’s Office of Enforcement deviations as little as a penny.

“Monitoring is not always clear and concise,” Ross said. “We have concerns with moving forward with that request. There’s no room for error when updating offers for fuel-price changes, and the burden of implementation is on the market participants to run the calculations. You could be one penny over the line because of a rounding error. You could violate the Tariff without any impact to the market.”

z2 task force spp mopc
MMU Executive Director Keith Collins | © RTO Insider

Keith Collins, the Market Monitoring Unit’s newly installed executive director, agreed with Ross. (See SPP Names CAISO’s Collins to Lead MMU.)

“There has to be a bright line. Yes, it’s a violation, but let’s exercise some judgment first,” he said. “It’s been my experience with manuals and protocols that … they’re nice guidance, but if you get to a circumstance where [they have] to be enforced, they don’t carry the same weight.”

Staff and members, in agreeing to send RR221 back to the MWG, said the issue was more of a market design problem.

“Let the market design experts take another shot at this,” said Midwest Energy’s Bill Dowling. “I’d prefer to see them deal with this issue one more time. Maybe there’s a way to navigate this.”

Wind Integration Study’s Recommendations Move On

The MOPC unanimously approved staff study recommendations for how much wind energy the SPP system can reliably absorb. The RTO has routinely broken the 50% penetration level for wind and has said it can go even higher. (See SPP Eyes 75% Wind Penetration Levels.)

SPP set a record for North American RTOs in April when wind energy served 54.47% of its load — 58.67% with the addition of solar and hydro. The RTO had 15.7 GW of installed wind capacity when the study began last year and currently projects 17.2 GW by the end of 2017.

Casey Cathey, SPP’s manager of operations analysis and support, said wind has exceeded 50% penetration several times and exceeded that mark for hours at a time.

“We’re meeting all NERC standards, but there are things out there we can continually improve on,” he said.

Last year’s Variable Generation Integration Study (VIS) stressed the transmission system to a point of instability, identifying reliability impacts during high-wind and low-load scenarios. Staff analyzed 45% and 60% wind penetration levels and examined transient stability, frequency response, voltage stability and a targeted five-minute ramping.

The VIS recommends seven solutions and improvements to increase reliability, including the installation of online transient-stability and voltage-stability analysis tools. Staff has estimated the software will cost a combined $3.2 million.

Members OK Re-baselining Out-of-Bandwidth Projects

Members unanimously approved re-baselining four out-of-bandwidth projects, three of which were a combined $95.5 million less than original estimates once project owners lowered material, engineering and construction costs through more accurate data.

One estimate, an OG&E 500/161-kV transformer project, went from $15.1 million to $25.6 million because of an increase in internal costs, unforeseen site work and the need to keep the 161-kV lines energized throughout the project.

All four projects were regionally funded, with operating voltages of greater than 100 kV and cost estimates of more than $20 million. (The OG&E project was a legacy project.) They became eligible for re-baselining when their updated cost estimates exceeded the +/-20% variance bandwidth after receiving notifications to construct.

MOPC Approves 9 Revision Requests

The MOPC approved a modified two-year-old revision request (RR82) that ensures combined cycle units do not lose eligibility for start-up cost MWPs because of a physical or environmental limitation, avoiding outage deviation penalties in the process.

RR82 adds a previously discussed increase in the MWPs’ grace period for commitments from one hour to two. The revision’s implementation date was scheduled for this August to allow SPP to complete development of software that allows market participants to register and submit separate offers for combined cycle units’ multiple configurations.

Final approval of the revision request is contingent upon the Regional Tariff Working Group’s endorsement of Tariff language changes. RR82 was approved by the MOPC and board in October 2015, but staff identified the additional changes while developing the FERC filing letter.

The committee approved eight other revision requests as part of its consent agenda, which passed unanimously:

  • MWG-RR185: Clarifies which SPP criteria document (Planning Criteria or Operating Criteria) is referenced when used in the market protocols and the Tariff’s Attachment AE, and correctly directs users to the specific document.
  • MWGRR210: Changes the process for testing a contingency reserve deployment (CRD) by adding a deployment test instruction issued in conjunction with the out-of-merit energy dispatch, allowing sufficient time to review test results and provide accurate data. Also changes SPP’s communication of the CRD’s test results from 60 minutes to within one business day. Should a resource retest be requested, SPP agrees to complete the test within two business days, subject to its assessment of system stability.
  • MWG-RR222: Includes a multiconfiguration combined cycle resource’s (MCR) committed and actual configuration for each interval in a bill determinant report, allowing MCRs to shadow the configuration SPP is using to settle these resources.
  • MWG-RR225: Cleans up confusing and misleading Tariff language on incremental long-term congestion rights (ILTCRs) that could construe ILTCRs as load-serving entities or non-LSEs.
  • MWGRR226: Changes settlement location pairs that have potential for unconstrained flow to electrically equivalent settlement locations during the auction revenue rights process, to comply with a FERC order (ER17-310). SPP will post the settlement locations before the annual ARR allocation process, along with the system topology and other data.
  • MWG-RR229: Satisfies FERC Order 831’s requirements on energy offer caps by using actual costs for make-whole payments on offers above $1,000/MWh. According to the order, costs underlying a resource’s cost-based incremental energy offer above $1,000/MWh must be verified before that offer can be used to calculate LMPs.
  • ORWG-RR228: Clarifies existing planning criteria language for system operating limits to reduce the potential of misinterpretation by entities complying with NERC reliability standards.
  • RTWG-RR233: Ensures that eligible network customers will not be billed twice for the same delivery. Customers will also not be assessed charges against a specific use of a single owner’s facilities that do not receive the benefit those charges provide to other transmission owners under the Tariff. The Southwestern Power Administration (SPA) and SPP have entered into a contract (Attachment AD) that provides for SPP to offer transmission service on SPA’s facilities, including network integration transmission service (NITS), and allows SPA to participate in the RTO’s transmission planning. SPA also voluntarily contributes to Schedule 11 representative of the grandfathered transmission service agreements (GFAs) it has in place for non-federal uses of its transmission facilities. SPA and SPP are transitioning customers with GFAs to NITS under the Tariff, creating implications for new customers who also receive federal hydropower deliveries.

The consent agenda also included:

  • Modifications to the revamped revision process, adding the Integrated Transmission Planning Manual and certain technical documents to the approval process. (See “Changes Proposed for Revision Process,” SPP Markets and Operations Policy Committee Briefs.)
  • The scope for the expedited re-evaluation of the Kummer Ridge-Roundup 345-kV line. (See “MOPC Endorses Re-evaluation of Basin Electric Project,” SPP Markets and Operations Policy Committee Briefs.)
  • A waiver request to FERC restating settlement prices for transmission congestion rights (TCRs) at Omaha Public Power District’s Fort Calhoun nuclear plant site. The plant was retired Dec. 1, 2016, but incorrect modeling of shift factors from Dec. 1 to Dec. 14, 2016, resulted in the marginal congestion component being overstated and the TCR settlements sourcing at the location being understated.

— Tom Kleckner

MISO Members: Court Rebuff May Reduce External Zone Chances

By Amanda Durish Cook

MISO last week presented stakeholders with a proposal to tighten rules on capacity imports amid uncertainty over whether a recent appellate court ruling will impact FERC’s ability to approve the changes.

In early July, the D.C. Circuit Court of Appeals eliminated portions of PJM’s minimum offer price rule that have been in place since 2013, ruling that FERC overstepped its authority when it suggested changes to a PJM proposal that resulted from a compromise among stakeholders. The court said although FERC can make minor changes to Tariff filings, it cannot substitute its own plan and must approve or reject an RTO proposal as is. (See PJM MOPR Order Reversed; FERC Overstepped, Court Says.)

MISO’s proposal — which would integrate external resources zones into the Planning Resource Auction using a single clearing price for each external balancing authority — has been met with a mixed stakeholder response. As a result, some stakeholders think the RTO should hit pause on a proposed September FERC filing and continue working for a proposal that has broad support.

MISO external resource zones
| MISO

FERC’s Power Diminished?

MISO Assistant General Counsel Michael Kessler said that the appellate ruling means FERC’s power may be diminished when it regains its quorum. (See related story, Trump Names Energy Lawyer McIntyre as FERC Chair.)

“It’s sort of a new package of standards. As it stands now, it’s a definite limitation on the commission’s authority to accept changes on a Section 205 filing,” Kessler said during a July 12 Resource Adequacy Subcommittee meeting.

Kessler said there is some ambiguity in the ruling on the distinction between significant changes that FERC is prohibited from suggesting and minor changes the commission can order.

“This isn’t just a PJM, MISO issue; it’s an industry issue. Any filing party will have to consider what FERC can and can’t do now since the back-and-forth that we’ve gotten used to [since the 1990s]. That route is not going to be available anymore. The whole industry will be carefully reviewing this to see the implications on filings going forward,” Kessler said. He added that all pending appeals of FERC-ordered changes could be up for reinterpretation.

Stakeholders said that with FERC expressly prohibited from ordering changes to RTO proposals, chances of the commission approving the contentious locational proposal may be smaller.

Customized Energy Solutions’ David Sapper, representing MISO’s Load-Serving Entity Coalition, said the ruling may signal to MISO that it’s time to only pursue filings with majority stakeholder support.

Last month, Sapper and the coalition made a motion to delay the locational proposal in favor of a capacity transfer rights proposal that would treat long-term supply arrangements involving external resources the same as internal planning resources. (See Changing Course, MISO Adopts IMM External Resource Zone Plan.) Stakeholders later passed the motion in an email vote 34-11 with three abstentions.

MISO external resource zones
McFarlane | © RTO Insider

MISO Executive Director of Strategy Shawn McFarlane reminded stakeholders that the motion is only treated as advice and is not binding. He said the motion signals to the RTO that more discussion with stakeholders is needed.

“So, we think we need some follow-up conversations,” he said. “We’ll be reaching out to stakeholders over the next few weeks. … We think some one-on-ones is going to be appropriate.”

McFarlane added that MISO will be making sure that the stakeholders that voted in favor of the motion understand the locational proposal; he said it would look for some possible modifications as well.

Asked if FERC would reject the filing without consensus among MISO and its stakeholders, McFarlane said it was too early for speculation and that the RTO still has time to alter its proposal.

Combined Filing Likely

Indianapolis Power and Light’s Ted Leffler asked if MISO has considered filing the locational proposal separately from hedging rules so the external location zone filing is not rejected based on its proposed approach on allocating excess auction revenues.

MISO has proposed that auction revenues be first handed to resources with historical commitments, with pre-RTO formation capacity arrangements and pre-locational capacity arrangements given first consideration for funding. External resources with contracts to MISO load affected by the proposal are next in line before the RTO doles out revenues as usual using an existing zonal deliverability benefit assessment.

McFarlane said MISO has considered separate filings but is still leaning toward a combined filing.

Leffler asked how many external capacity resources will become unmarketable because of a low clearing price and the lack of a historic capacity agreement.

“I think it’s important that we understand how much is at risk here,” Leffler said. “The auction clearing prices are very sensitive to changes in supply and demand.”

“We don’t feel like we have a choice but to address the potential reliability issue from our current approach here,” McFarlane said. He added that MISO is eyeing a “reasonable” approach that can win FERC approval.

Some stakeholders are still asking MISO for more details on how external resources are treated based on geographic distance from the RTO’s footprint. They asked that prices be based on a resource’s proximity to loads inside MISO instead of a uniform external balancing authority price.

Laura Rauch, MISO manager of resource adequacy coordination, said that except for resources near a border, the RTO sees no difference in deliverability in resources situated “150 miles away from MISO or 300 miles from MISO.” Its concern is whether a resource in Chicago or New Jersey can deliver against Lower Michigan’s clearing requirement “as well as a Detroit resource,” she said.

PJM PC/TEAC Briefs: July 13, 2017

PJM Maintaining Separate Load Peaks in Model

VALLEY FORGE, Pa. — The Planning Committee last week approved PJM’s recommendation to use 10-year historical data from 2003 to 2012 and to change the “world” peak week in its 2017 reserve requirement study.

transmission expansion advisory committee pjm
Rocha-Garrido | © RTO Insider

PJM’s Patricio Rocha-Garrido told stakeholders the RTO decided to separate its peak load from that of the “rest of world” because of software limitations. Coincident peak distributions from the PJM load forecast cannot be used directly in its PRISM (probabilistic reliability index study model) software, which handles model uncertainty by week rather than day-by-day.

“The world” comprises of neighbors MISO, New York, the Tennessee Valley Authority and SERC Reliability’s VACAR region in Virginia and the Carolinas — areas from which the RTO would seek to import generation if it runs short.

(See “ISO-NE out of this ‘World,’ According to PJM Reserve Requirement Study,” PJM Planning Committee/TEAC Briefs.)

“When we have PJM and ‘the world’ peaking on the same week, effectively we’re having PJM and ‘the world’ peaking on the same day,” Rocha-Garrido said.

However, over the past 18 years, PJM and “the world” have peaked simultaneously eight times, while they have not peaked together 10 times.

In response, PJM moved the world peak to Week 11 in the summer and retained its peak on Week 10 to match the “historical diversity” in peaks.

Rocha-Garrido said the 2003-2012 load model, which was also used in last year’s study, was “a close second place” to the top-ranked 2004-2012 time period but had the advantage of an extra year of data.

“We do not see evidence to change that this year,” he said.

The recommendation was endorsed by acclamation, with no objections or abstentions.

RTEP Cycle Revisions Approved

The committee approved revisions to the rules for the Regional Transmission Expansion Plan, agreeing to extend the cycle from one year to 18 months.

PJM’s Amanda Long said the planning cycle will begin in September and run through February of the following calendar year. A new cycle will begin every September, overlapping the previous cycle. (See PJM Making Cost Consciousness a Focus for RTEP Redesign.)

| PJM

The committee also approved Operating Agreement changes to extend the 30-day competitive proposal window for short-term projects to 60 days beginning about June annually. The long-term proposal window will remain at 120 days.

The proposal was endorsed by acclamation, with no objections or abstentions.

Resilience to Become Planning Driver

Sims | © RTO Insider

PJM’s Mark Sims explained how the RTO’s recent focus on resilience will impact its planning processes.

NERC’s standards require PJM to consider in its planning critical “stressed” conditions so it can manage the system regardless of actual conditions on any day. In addition, NERC requires the RTO to conduct a system assessment and explore potential solutions of low-probability “extreme” events.

As a result, Sims said, PJM will seek to identify “worst offenders,” such as circuits that frequently are involved in low-probability events. (See “PJM Reconsidering Planning Assumptions,” PJM Planning & Tx Expansion Advisory Committees Briefs.)

“It’s not involved in one low-probability event; it’s involved in many. So in my opinion, it’s no longer low-probability,” Sims said, adding that it “might” make sense to fix these issues.

John Farber of the Delaware Public Service Commission reiterated his concerns from a similar conversation during the Operating Committee meeting earlier in the week.

“There are major issues with implementing resilience as a standalone driver in the RTEP,” he said. “Achieving a sufficient level of objectivity to justify its inclusion as a standalone driver in the RTEP is just a difficult challenge to deal with.”

He said it will be difficult to develop objective cost and benefits criteria to justify millions in spending, especially when individual states may have different viewpoints on spending the money.

Greg Poulos of the Consumer Advocates of the PJM States agreed. Developing appropriate metrics will be important to determine how goals will be achieved, he said. The timeline is another issue, he said.

“There’s a lot of concern about things adding up,” he said. “I certainly agree it’s an evolution, but the consumer advocates are concerned it’s a slippery slope. Where does it begin and where does it end?”

Sims assured stakeholders it would be a “very deterministic” process. “I think this paradigm is going to be a little bit of a shift,” he said.

Winter Evaluation

PJM’s Tom Falin provided an update on the RTO’s analysis of winter resource adequacy and capacity requirements, the subject of an issue charge approved by stakeholders last year. The details highlighted the differences across the RTO. (See “Winter Resource Adequacy Analysis Raises Questions,” PJM Planning & Transmission Expansion Advisory Committee Briefs.)

An analysis of the ratio between the winter and summer peaks in each locational deliverability area (LDA) found that the East Kentucky Power Cooperative was the heaviest winter peaking LDA in the RTO, with a winter-summer ratio at about 1.3. The RTO itself is mostly summer peaking with a ratio of .87, and Rockland Electric is the heaviest summer-peaking LDA with a ratio of about .59.

“The heaviest summer-peaking LDAs are basically [in] New Jersey,” Falin said.

The loss-of-load expectation analysis results found that, even including the outliers from the winter of 2014-15 that included the polar vortex effects, and assuming historical forced outages and the maximum historical planned outages, the LOLE was .02 days/year. Falin noted that these numbers only included generator forced outages and that transmission outages would need to be considered as well.

Going forward, Falin said PJM will compute summer and winter reliability requirements for the RTO and selected LDAs while continuing to investigate a winter load forecast model.

Solar Capacity Factors Class Averages

PJM has updated its capacity factors for wind and solar based on actual summer data from 2014-2016.

PJM’s Jerry Bell said the analysis found that wind turbines have a capacity factor of 14.7% in mountainous terrain during peak summer hours between 3 and 6 p.m. and 17.6% in open, flat terrain during the same period. Solar capacity factors ranged from 60% for ground-mounted arrays that track the sun, to 42% for fixed ground-mounted panels, to 38% for all panel types other than ground-mounted.

The capacity factor affects generators’ capacity revenues and a project’s entitlement to capacity injection rights.

Renewable developers can request higher capacity factors for their projects if they can provide evidence to prove their generators operate at higher levels.

The study hasn’t yet considered how capacity factors are affected by degradation of the equipment over time, but Bell said it will be added in the future. Several stations were removed from the analysis because they displayed obvious degradation over time, he said. Degradation is, however, factored into CIRs for stations, he said.

Transmission Expansion Advisory Committee

Transmission Proposal Window Opens

PJM opened a 45-day window last week seeking proposed transmission projects to fix reliability criteria violations on 43 flowgates. The window will close on Aug. 25.

The flowgates were identified in the 2022 analysis: 34 in PJM’s Western Region, six in the Southern Region and three in the Mid-Atlantic Region. The remaining 161 flowgates from the analysis were excluded from the window as either immediate-need projects or under 200 kV, which is PJM’s threshold for opening projects to competitive bidding. The RTO has found that projects under 200 kV tend to be upgrades handled by the incumbent transmission owner.

Updates to AI Analysis

Staff have updated PJM’s beneficiary analysis for the Artificial Island project to address issues raised by stakeholders at the June 9 special Transmission Expansion Advisory Committee meeting. Among the additions was a list of transmission facilities that could compose a stability interface.

Most of the $280 million bill for the project would shift from Delaware to New Jersey and Pennsylvania under two alternative methodologies outlined in the analysis. But it will be up to PJM’s TOs to petition FERC to adopt a new methodology for the project. “PJM does not have the authority to devise or file allocation methodologies as federal law makes clear that the Section 205 filing rights over rates and cost allocation in this area rests with the PJM transmission owners,” the report says.

The project, PJM’s first foray into competitive bidding under FERC Order 1000, has been bogged down in stakeholder infighting for years. In April, PJM’s Board of Managers lifted a suspension on the project and re-awarded it to LS Power. (See PJM: AI Costs Would Shift to NJ, PA Under New Allocations.)

— Rory D. Sweeney